본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구

이용수 0

영문명
A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT
발행기관
대한핵의학기술학회
저자명
조석원(Seok Won Cho) 박훈희(Hoon-Hee Park) 김정열(Jung Yul Kim) 반영각(Yung Kak Ban) 임한상(Han Sang Lim) 오기백(Ki Beak Oh) 김재삼(Jae Sam Kim) 이창호(Chang Ho Lee)
간행물 정보
『핵의학기술』Vol.14 No.2, 159~165쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2010.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to ⁹⁹ᵐTc emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: 47.7±6.6, mean height: 165.5±3.8 cm and mean weight: 65.9±1.4 kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 μSv/h) was the highest and foot (15.85 μSv/h) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 μSv/h, 5.23 μSv/h, and 3.40 μSv/h in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 μSv/h, 1.67 μSv/h, and 1.27 μSv/h in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 μSv/h, 4.90 μSv/h, 3.44 μSv/h in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 μSv/h, 1.34 μSv/h, and 1.13 μSv/h in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 μSv/h, 5.15 μSv/h and 3.18 μSv/h in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 μSv/h, 1.75 μSv/h and 1.23 μSv/h in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

목차

서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

조석원(Seok Won Cho),박훈희(Hoon-Hee Park),김정열(Jung Yul Kim),반영각(Yung Kak Ban),임한상(Han Sang Lim),오기백(Ki Beak Oh),김재삼(Jae Sam Kim),이창호(Chang Ho Lee). (2010).PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구. 핵의학기술, 14 (2), 159-165

MLA

조석원(Seok Won Cho),박훈희(Hoon-Hee Park),김정열(Jung Yul Kim),반영각(Yung Kak Ban),임한상(Han Sang Lim),오기백(Ki Beak Oh),김재삼(Jae Sam Kim),이창호(Chang Ho Lee). "PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구." 핵의학기술, 14.2(2010): 159-165

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제