본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

CT 선량 측정 프로그램을 이용한 PET/CT 검사 환자의 예측 유효 선량의 분석

이용수 0

영문명
Analysis of Patient Effective Dose in PET/CT; Using CT Dosimetry Programs
발행기관
대한핵의학기술학회
저자명
김정선(Jung Sun Kim) 정우영(Woo Young Jung) 박승용(Seung Yong Park)
간행물 정보
『핵의학기술』Vol.14 No.2, 77~82쪽, 전체 6쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2010.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: As PET/CT come into wide use, it caused increasing of expose in clinical use. Therefore, Korea Food and Drug Administration issued Patient DRL (Diagnostic Reference Level) in CT scan. In this study, to build the basis of patient dose reduction, we analyzed effective dose in transmission scan with CT scan. Materials and Methods: From February, 2010 to March 180 patients (age: 55±16, weight: 61.0±10.4 kg) who examined ¹⁸F-FDG PET/CT in Asan Medical Center. Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY) and Discovery STe8 (GE healthcare, USA) were used in this study. Per each male and female average of 30 patients doses were analyzed by one. Automatic exposure control system for controlling the dose can affect the largest by a patient’s body weight less than 50 kg, 50-60 kg less, 60 kg more than the average of the three groups were divided doses. We compared that measured value of CT-expo v1.7 and ImPACT v1.0. The relationship between body weight and the effective dose were analyzed. Results: When using CT-Expo V1.7, effective dose with BIO40, BIO16 and DSTe8 respectably were 6.46±1.18 mSv, 9.36±1.96 mSv and 9.36±1.96 mSv for 30 male patients respectably 6.29±0.97 mSv, 10.02±2.42 mSv and 9.05±2.27 mSv for 30 female patients respectably. When using ImPACT v1.0, effective dose with BIO40, BIO16 and DSTe8 respectably were 6.54±1.21 mSv, 8.36±1.69 mSv and 9.74±2.55Sv for 30 male patients respectably 5.87±1.09 mSv, 8.43±1.89 mSv and 9.19±2.29 mSv for female patients respectably. When divided three groups which were under 50 kg, 50~60 kg and over 60 kg respectably were 6.27 mSv, 7.67 mSv and 9.33 mSv respectably using CT-Expo V1.7, 5.62 mSv, 7.22 mSv and 8.91 mSv respectably using ImPACT v1.0. Weight and the effective dose coefficient analysis showed a very strong positive correlation(r=743, r=0.693). Conclusion: Using such a dose evaluation programs, easier to predict and evaluate the effective dose possible without performing phantom study and such dose evaluation programs could be used to collect basic data for CT dose management.

목차

서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김정선(Jung Sun Kim),정우영(Woo Young Jung),박승용(Seung Yong Park). (2010).CT 선량 측정 프로그램을 이용한 PET/CT 검사 환자의 예측 유효 선량의 분석. 핵의학기술, 14 (2), 77-82

MLA

김정선(Jung Sun Kim),정우영(Woo Young Jung),박승용(Seung Yong Park). "CT 선량 측정 프로그램을 이용한 PET/CT 검사 환자의 예측 유효 선량의 분석." 핵의학기술, 14.2(2010): 77-82

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제