PET/CT 영상에서의 치과재료에 의한 인공물에 관한 연구

이용수 0

영문명
Evaluation of Artifacts by Dental Metal Prostheses and Implants on PET/CT Images: Phantom and Clinical Studies
발행기관
대한핵의학기술학회
저자명
반영각(Young Kag Bahn) 박훈희(Hoon-Hee Park) 남궁혁(Hyuk Nam-Koong) 조석원(Suk Won Cho) 임한상(Han Sang Lim) 이창호(Chang Ho Lee)
간행물 정보
『핵의학기술』Vol.14 No.2, 110~116쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2010.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: The X-ray attenuation coefficient based on CT images is used for attenuation correction in PET/CT. The polychromatic X-ray beam can introduce beam-hardening artifact on CT images. The aims of the study were to evaluate the effect of dental metal prostheses in phantom and patients on apparent tracer activity measured with PET/CT when using CT attenuation correction. Materials and Methods: 40 normal patients (mean age 54±12) was scanned between Jan and Feb 2010. NEMA(National Electrical Manufactures Association) PET PhantomTM (NU2-1994) was filled with ¹⁸F-FDG injected into the water that insert implant and metal prostheses dental cast. Region of interest were drawn in non-artifact region, bright steak artifact region and dark streak artifact region on the same transaxial CT and PET slices. Patients and phantom with dental metal prostheses and dental implant were evaluated the change rate of CT Number and SUVmean in PET/CT. A paired t-test was performed to compare the ratio and the difference of the calculated values. Results: In patients with dental metal prostheses, SUVₘₑₐₙ was reduced 19.64% (p<0.05) in the non-steak artifact region than the brightstreak artifact region whereas was increased 90.1% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental metal prostheses, SUVₘₑₐₙ was reduced 18.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 18.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In patients with dental implant, SUVₘₑₐₙ was increased 19.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 96.62% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental implant, SUVₘₑₐₙ was increased 14.4% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 7.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. Conclusion: When CT is used for attenuation correction in patients with dental metal prostheses, 19.1% reduced SUVₘₑₐₙ is anticipated in the dark streak artifact region on CT images. The dark streak artifacts of CT by dental metal prostheses may cause false negative finding in PET/CT. We recommend that the non-attenuation corrected PET images also be evaluated for clinical use.

목차

서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

반영각(Young Kag Bahn),박훈희(Hoon-Hee Park),남궁혁(Hyuk Nam-Koong),조석원(Suk Won Cho),임한상(Han Sang Lim),이창호(Chang Ho Lee). (2010).PET/CT 영상에서의 치과재료에 의한 인공물에 관한 연구. 핵의학기술, 14 (2), 110-116

MLA

반영각(Young Kag Bahn),박훈희(Hoon-Hee Park),남궁혁(Hyuk Nam-Koong),조석원(Suk Won Cho),임한상(Han Sang Lim),이창호(Chang Ho Lee). "PET/CT 영상에서의 치과재료에 의한 인공물에 관한 연구." 핵의학기술, 14.2(2010): 110-116

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제