¹⁸F-FDG를 이용한 전신 PET 검사에서 혈당 측정 검사지의 정확한 사용에 따른 혈당 수치의 차이 분석

이용수 0

영문명
The Analysis of Blood Glucose Level Difference According to the Exact Use of Blood Glucose Measurement Test Strips in ¹⁸F-FDG Wholebody PET
발행기관
대한핵의학기술학회
저자명
박순기(Soon Ki Park) 이남기(Nam Ki Lee) 남궁창경(Chang Kyung Namgung) 정우영(Woo Young Jung)
간행물 정보
『핵의학기술』Vol.14 No.2, 100~103쪽, 전체 4쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2010.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: ¹⁸F-FDG wholebody PET is to evaluate the tumor using glucose metabolism. The blood glucose level is important factor that affects on a result of examination. High glucose levels may interfere with tumor targeting due to competitive inhibition of FDG uptake by D-glucose. The blood glucose level measurement test strips used in the blood glucose measurement are classified into the capillary blood measurement test strips and general purpose measurement test strips that can measure the venous blood and capillary blood altogether depends on cases. The purpose of the study was to compare the blood glucose measurements between simultaneously obtained capillary and venous blood samples using the capillary blood measurement test strips, general purpose measurement test strips. Materials and Methods: A total of 46 subjects (32 males, 14 females) with a mean age of 57.3±12.3 years were enrolled. The blood glucose estimation was performed with a Optium Xceed Glucometer (Abbott). Simultaneous capillary and venous blood samples were obtained from each subject. The blood glucose levels were measured using the capillary blood measurement test strips and general purpose measurement test strips. The capillary and venous measurements were compared using a pared t-test. Results: The mean capillary and venous glucose values using the general purpose measurement test strips were 95.2±12.4 mg/dL and 104.1±14.4 mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (9.0 mg/dL; 95% confidence interval (CI) -11.2 to -6.7). The mean capillary and venous glucose values using the capillary blood measurement test strips were 91.5±13.6 mg/dL and 108.6±16.2 mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (16.6 mg/dL; 95% CI -20.2 to -13.0). Conclusion: When measuring the blood glucose level before ¹⁸F-FDG PET examination, since the incorrect blood glucose level can be measured, it should note to measure the blood glucose level of the venous blood by the capillary blood measurement test strips. Therefore the measurement variation can be reduced to fulfill the standardized measurement procedure with the suitable measurement test strips, the preparation of the PET examination will be able to be clearly confirmed. In addition, the standardized procedure of the following measurement on the area which is same at all times the blood area in the blood glucose measurement among a capillary or a vein will be needed.

목차

서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

박순기(Soon Ki Park),이남기(Nam Ki Lee),남궁창경(Chang Kyung Namgung),정우영(Woo Young Jung). (2010).¹⁸F-FDG를 이용한 전신 PET 검사에서 혈당 측정 검사지의 정확한 사용에 따른 혈당 수치의 차이 분석. 핵의학기술, 14 (2), 100-103

MLA

박순기(Soon Ki Park),이남기(Nam Ki Lee),남궁창경(Chang Kyung Namgung),정우영(Woo Young Jung). "¹⁸F-FDG를 이용한 전신 PET 검사에서 혈당 측정 검사지의 정확한 사용에 따른 혈당 수치의 차이 분석." 핵의학기술, 14.2(2010): 100-103

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제