영문 초록

Purpose: Ejection fraction (EF) is one of the most important factors that evaluate heart function. Recently, according to echocardiography and myocardial perfusion SPECT, the number of gated blood pool scan (planar GBP) is declining. Measurement of left ventricular ejection fraction using gated blood pool SPECT (GBPS) is known as relatively correspond with echocardiography. We compared EF derived from plnar GBP, GBPS and echocadiography using modified simpson method to determine the accuracy. Materials and Methods: From January 2007 to June 2010, planar GBP and GBPS were performed on 34 patients who admitted to Pusan National University Hospital (men 23, women 11, mean age 52.6±27.2). Each patient was injected with ⁹⁹ᵐTcO₄-of 20 mCi after pyrophosphate injection and then scanned using both planar GBP and GBPS techniques. For image analysis, we use ADAC Laboratories, Ver. 4.20 software. The result analyzed was processed by SPSS 17.0 Win statistic program and statistical method applied in data analysis is one-way anova, Tukey’s post hoc test, pearson correlation test. Results: One-way anova test show no significant difference (planar GBP 56.3±13.9%; GBPS 60.4±16.0%; echocardiography 59.1±14.4%, p=0.486, p>0.05). Tukey’s post hoc test show no significant difference (planar GBP-echocardiography p=0.697; GBPS-echocardiography p=0.928; planar GBP-GBPS p=0.469, p>0.05). Values for EF obtained with planar GBP and GBPS correlated well with those obtained with echocardiography (planar-echocardiography r=0.697; GBPS-echocardiography r=0.928; planar GBP-GBPS r=0.469). Conclusion: The problems of accuracy and reproducibility for planar GBP still remain. But planar GBP is a safe and non-invasive method. In addition, planar GBP is useful to evaluate patient with low resolution echocardiography images. GBPS is not appicated clinically. but GBPS can be obtain various left ventricular functional parameters. planar GBP, GBPS and echocardiography show a good correlation between each other. Therefore, planar GBP and GBPS are useful for evaluating left ventricular ejection fraction.

목차

서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

정지욱(Ji Uk Jeong),이효영(Hyo Yeong Lee),윤종준(Jong-Jun Yun),이화진(Hwa-jin Lee),이무석(Moo-Seok Lee),송현석(Hyeon-Seok Song),박세윤(Se-Yun Park),김재환(Jae-Hwan Kim). (2010).게이트심장혈액풀스캔과 게이트심장혈액풀 SPECT로 측정한 심박출계수의 심초음파와의 비교 연구. 핵의학기술, 14 (2), 150-154

MLA

정지욱(Ji Uk Jeong),이효영(Hyo Yeong Lee),윤종준(Jong-Jun Yun),이화진(Hwa-jin Lee),이무석(Moo-Seok Lee),송현석(Hyeon-Seok Song),박세윤(Se-Yun Park),김재환(Jae-Hwan Kim). "게이트심장혈액풀스캔과 게이트심장혈액풀 SPECT로 측정한 심박출계수의 심초음파와의 비교 연구." 핵의학기술, 14.2(2010): 150-154

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제