본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

방사성오염물질 처분에 대한 고찰

이용수 0

영문명
Consideration of Radioactive Contamination Materials Disposal
발행기관
대한핵의학기술학회
저자명
임현진(Hyun Jin Im) 김태엽(Tae Yeob Kim) 이홍재(Hong Jae Lee) 김진의(Jin Eui Kim) 김현주(Hyun Joo Kim)
간행물 정보
『핵의학기술』Vol.14 No.2, 128~132쪽, 전체 5쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2010.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: Nuclear medicine general operation room is radioactive control room which is used for the handling of radioisotope(R.I). Radioactive contamination materials must be under control and separated from general trash. With this experiments, we want to actively suggest the guideline of controling and operating radioactive contamination materials by measuring contamination degree and analyzing the causes which is not realized so far. Materials and Methods: Materials are selected from Oct. 2009 to March. 2010. salines which are used for labelling radiophamaceuticals and generator cap, saline needle cap, ⁹⁹ᵐTc-needle cap saline vial which is generated from ⁹⁹ᵐo/⁹⁹ᵐTc generator. After measuring each surface contamination degree by survey meter, mean value and standard deviation one were solved out. Results: In result, After measuring surface contamination degree, radioactivity of saline for labelling radiophamaceuticals showed 14429±26378 cpm (p<0.05) and in measured generators, foreign imported things showed that generator cap : 9±21 cpm, saline vial : 17±28 cpm. saline needle cap : 35±66 cpm, ⁹⁹ᵐTc-needle cap : 9±21 cpm, saline vial 13±28 cpm. domestic things showed that generator cap : 22852±52545 cpm, saline needle cap : 87367±109711 cpm, ⁹⁹ᵐTc-needle cap : 9008±10459 cpm, saline vial : 186416±158196 cpm (p<0.05). Conclusion: The saline which is used for labelling, exceeded 1/10 of maximum permissible range. this is generated from radiophamaceuticals dilution procedure. and In generators, radioactive value of foreign import things showed closely background value. but which of domestic thing showed that exceeded more than 1000 values 1/10 of maximum permissible range. the causes of that is domestic generator is contaminated in manufacturing procedure. So, to dispose radioactive contamination materials which is could betaken out of, the control and operation must be radical under controlled by radioactive measuring, recording and equipping of its own. if this is kept well, we can prevent surely that radioactive waste could be disposed like as general trash.

목차

서론
실험재료 및 방법
결 과
결론 및 고찰
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

임현진(Hyun Jin Im),김태엽(Tae Yeob Kim),이홍재(Hong Jae Lee),김진의(Jin Eui Kim),김현주(Hyun Joo Kim). (2010).방사성오염물질 처분에 대한 고찰. 핵의학기술, 14 (2), 128-132

MLA

임현진(Hyun Jin Im),김태엽(Tae Yeob Kim),이홍재(Hong Jae Lee),김진의(Jin Eui Kim),김현주(Hyun Joo Kim). "방사성오염물질 처분에 대한 고찰." 핵의학기술, 14.2(2010): 128-132

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제