본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Cisternography 검사 시 사용되는 방사성의약품의 안정성 확보를 위한 검사도입 및 유용성 평가

이용수 0

영문명
Evaluation of Usefulness and Procedures for Safety of Radiopharmaceuticals in Cisternography
발행기관
대한핵의학기술학회
저자명
김다은(Da Eun Kim) 유연욱(Yeon Wook Yoo) 최호용(Ho Yong Choi) 김윤철(Yun Cheol Kim) 김영석(Yeong Seok Kim) 원우재(Woo Jae Won) 김석기(Seok Ki Kim)
간행물 정보
『핵의학기술』Vol.14 No.2, 45~49쪽, 전체 5쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2010.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: Several radiopharmaceuticals were used for cisternography. But recently, due to more short acquisition time, high resolution than other radiopharmaceuticals like In-111 DTPA, we were using Tc-99m DTPA in cisternography. Using of Tc-99m DTPA for intrathecal, was not officially recognised by the FDA. And there are matters of aseptic meningitis, muscular tetany, seizures by inappropriate radiopharmaceuticals handling. So, it is necessary to prevent adverse reactions while handling the radiopharmaceuticals using in cisternography. Therefore, this study aims to evaluation of usefulness and procedures for safety of radiopharmaceuticals in cisternography. Materials and Methods: Subjects were 12radioactive tracer vials using in cisternography in 2008 Dec. 16 - 2009 Dec. 30. ① Radioactive tracer Vial test - We were measured NaPertechnetate radiation dose and volume, normal saline volume for dilution, source volume and dose activity for patient injection. And then, calculated mass of pure DTPA. ② Bacterial endotoxin test - We performed pyrogen test using by negative/ positive control vials which was added normal saline 0.2 mL and added normal saline 0.1 mL, Tc-99m DTPA 0.1 mL in test control vial. And then, reacted by digital hot plate in 37.5℃ for 1 hour and compared of gel-clot in each control vials. ③ Compliance safety procedure - We were checked safety issues and wrote out a safety procedure exam sheet. Results: ① Radioactive tracer Vial test - Mass of DTPA per dose for patient injection (mg) was 0.88 (mg) on average, and Mass of DTPA per volume for patient injection (mg) was 0.74 (mg) on average. ② Bacterial endotoxin test - All control test vials showed negative reactions. ③ Compliance safety procedure - We were checked safety issues and wrote out a safety exam sheet in all the exams. So, there were no adverse reactions. Conclusion: We could examine easier to safety tests using by Techscan - DTPA (Mallinckrodt): CaNa3. Each test results were passed the safety tests and there are no adverse reactions. The use of Tc-99m DTPA for cisternography, always has been become an issue. Since it has occur adverse reaction while examine the cisternography using by Tc-99m DTPA , it needs to set up the ’Standard Operating procedures’.

목차

서론
실험재료 및 방법
결과
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김다은(Da Eun Kim),유연욱(Yeon Wook Yoo),최호용(Ho Yong Choi),김윤철(Yun Cheol Kim),김영석(Yeong Seok Kim),원우재(Woo Jae Won),김석기(Seok Ki Kim). (2010).Cisternography 검사 시 사용되는 방사성의약품의 안정성 확보를 위한 검사도입 및 유용성 평가. 핵의학기술, 14 (2), 45-49

MLA

김다은(Da Eun Kim),유연욱(Yeon Wook Yoo),최호용(Ho Yong Choi),김윤철(Yun Cheol Kim),김영석(Yeong Seok Kim),원우재(Woo Jae Won),김석기(Seok Ki Kim). "Cisternography 검사 시 사용되는 방사성의약품의 안정성 확보를 위한 검사도입 및 유용성 평가." 핵의학기술, 14.2(2010): 45-49

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제