⁹⁹ᵐTc-DMSA 신장검사에서 획득 계수의 차이에 따른 기능 및 형태 평가

이용수 0

영문명
The Quantitative Assessment of Renal Function and Size by Differences of Acquisition Counts in ⁹⁹ᵐTc-DMSA Renal Scan
발행기관
대한핵의학기술학회
저자명
심동오(Dong Oh Shim) 김호성(Ho Sung Kim) 정은미(Eun Mi Chung)
간행물 정보
『핵의학기술』Vol.14 No.2, 117~121쪽, 전체 5쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2010.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: In nuclear medicine study, there are two methods, preset count method and preset time method, to acquire static images. We usually use preset count method for static image in ⁹⁹ᵐTc-DMSA renal scan, but occasionally use preset time method. In case of using preset count method, we always acquire same counts but it causes a difference of scan time. In case of using preset time method, it takes same scan time to acquire images but it causes different counts. Therefore, the purpose of this study is to investigate any differences of function and formal information in both kidney by acquisition counts Materials and Methods: From January 11, 2010 to March 31, 2010, we analyzed the 30 patients (M: 11, W: 19). who were examined by ⁹⁹ᵐTc-DMSA scan and have one side of functioning kidney relatively between 40~60%. And the patients who have cold and hot region in image were analyzed but we did not accept images of patients when it was hard to divide kidney into cortex. There was no division between subjects and age of subjects is 14.83±22.07 old. We used the BrightView gamma camera from PHILIPS. To analyze function and formal of kidney, we used JET stream release 3.0 version from PHILIPS. Using SPSS 12.0 program, we compared descriptive statistics and paired T-test. Images were acquired sequentially in the same parameters, but there are three methods which different from acquisition time and scan time, 100 kcounts, 300 kcounts and 7 minutes method (exceed 300 kcounts). To assess function and formal information of kidney, we measured renal relative function, geometric mean and size of kidney and analyzed each difference. Results: In case of renal relative function in both kidney, 100 kcounts method was 50.52±3.64%. 300 kcounts method was 50.38±3.66% and 7 minutes method was 49.91±3.40% and there were no statistical significant differences between each method. In case of geometric mean, 100 kcounts method was 50.08±3.25%. 300 kcounts method was 49.89±3.40% and 7 minutes method was 49.91±3.24%. And also, there were no statistical significant differences. When comparing size of kidney, 100 kcounts method was 8.23±1.96 cm. 300 kcounts method was 8.12±1.90 cm and 7 minutes method was 8.35±1.97 cm. In case of right kidney, 100 kcounts method was 7.91±1.88 cm. 300 kcounts method was 8.12±1.90 cm and 7 minutes method was 8.25±1.96 cm. From those values, we recognized that there were significant differences each method (p<0.05). Conclusion: From results of this study, there were no statistical differences in renal relative function and geometric mean by acquisition counts. However, in shape of kidney, the more acquisition counts are increasing, the more size of kidney is getting big. And there were statistical significant differences. Therefore, to perform reliable quantitative result, preset count method is more desirable than preset time method. Especially, in case of a follow-up test, if we use preset time method, it will cause differences of formal results in kidney due to acquisition counts each time we examine patients.

목차

서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

심동오(Dong Oh Shim),김호성(Ho Sung Kim),정은미(Eun Mi Chung). (2010).⁹⁹ᵐTc-DMSA 신장검사에서 획득 계수의 차이에 따른 기능 및 형태 평가. 핵의학기술, 14 (2), 117-121

MLA

심동오(Dong Oh Shim),김호성(Ho Sung Kim),정은미(Eun Mi Chung). "⁹⁹ᵐTc-DMSA 신장검사에서 획득 계수의 차이에 따른 기능 및 형태 평가." 핵의학기술, 14.2(2010): 117-121

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제