본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

유방암 환자에서 전신 뼈 검사 후 감시림프절 위치 파악 검사의 유용성

이용수 0

영문명
Usefulness of Breast Lymphoscintigraphy after Whole Body Bone Scan
발행기관
대한핵의학기술학회
저자명
장동근(Dong Gun Jang) 반영각(Young Kag Bahn) 정석(Seok Chung) 박훈희(Hoon Hee Park) 강천구(Chun Goo Kang) 임한상(Han Sang Lim) 김재삼(Jae Sam Kim) 이창호(Chang Ho Lee)
간행물 정보
『핵의학기술』Vol.14 No.2, 133~137쪽, 전체 5쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2010.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: Breast cancer is known to be more vulnerable to bone metastasis and lymph node metastasis than other types of cancer, and nuclear examinations whole body bone scan and lymphoscintigraphy are performed commonly before and after breast cancer operation. In case whole body bone scan is performed on the day before lymphoscintigraphy, the radiopharmaceutical taken into and remaining in the bones provides anatomical information for tracking and locating sentinel lymph nodes. Thus, this study purposed to examine how much bone density affects in locating sentinel lymph nodes. Materials and Methods: The subjects of this study were 22 patients (average age 52±7.2) who had whole body bone scan and lymphoscintigraphy over two days in our hospital during the period from January to December, 2009. In the blind test, 22 patients (average age 57±6.5) who had lymphoscintigraphy using ⁵⁷Co flood phantom were used as a control group. In quantitative analysis, the relative ratio of the background to sentinel lymph nodes was measured by drawing ROIs on sentinel lymph nodes and the background, and in gross examination, each of a nuclear physician and a radiological technologist with five years’ or longer field experience examined images through blind test in a five-point scale. Results: In the results of quantitative analysis, the relative ratio of the background to sentinel lymph nodes was 14.2:1 maximum and 8.5:1 (SD±3.48) on the average on the front, and 14.7:1 maximum and 8.5:1 (SD±3.42) on the average on the side. In the results of gross examination, when ⁵⁷Co flood phantom images were compared with images containing bones, the score was relative high as 3.86 (SD±0.35) point for ⁵⁷Co flood phantom images and 4.09 (SD±0.42) for bone images. Conclusion: When whole body bone scan was performed on the day before lymphoscintigraphy, the ratio of the background to sentinel lymph nodes was over 10:1, so there was no problem in locating lymph nodes. In addition, we expect to reduce examination procedures and improve the quality of images by indicating the location of sentinel lymph nodes using bone images as body contour without the use of a source.

목차

서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

장동근(Dong Gun Jang),반영각(Young Kag Bahn),정석(Seok Chung),박훈희(Hoon Hee Park),강천구(Chun Goo Kang),임한상(Han Sang Lim),김재삼(Jae Sam Kim),이창호(Chang Ho Lee). (2010).유방암 환자에서 전신 뼈 검사 후 감시림프절 위치 파악 검사의 유용성. 핵의학기술, 14 (2), 133-137

MLA

장동근(Dong Gun Jang),반영각(Young Kag Bahn),정석(Seok Chung),박훈희(Hoon Hee Park),강천구(Chun Goo Kang),임한상(Han Sang Lim),김재삼(Jae Sam Kim),이창호(Chang Ho Lee). "유방암 환자에서 전신 뼈 검사 후 감시림프절 위치 파악 검사의 유용성." 핵의학기술, 14.2(2010): 133-137

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제