OCS QC 프로그램을 통한 건진 센터 종양검사의 결과보고 개선

이용수 0

영문명
Improvement of the Result Related to Tumor Marker Test Through the OCS QC Program
발행기관
대한핵의학기술학회
저자명
백송란(Song Ran Back) 김성호(Sung ho Kim) 유소연(So Yeon Yoo) 김년옥(Nyun Ok Kim) 문형호(Hyoung ho Moon) 유선희(Seon Hee Yoo) 조시만(Shee Man Cho)
간행물 정보
『핵의학기술』Vol.13 No.2, 185~188쪽, 전체 4쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2009.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: Standard of retests were discrepant and inconsistent due to inaccuracy and lack of standardization within normal range limit of tumor marker test. To enhance the standardization of retests set standard value below normal range and the Order Communication System Quality Control (OCS QC) program was put in place. This program enables managing the results within lower limit of normal range which were used for tumor marker test in Health Center. Materials and Methods: At present the tumor marker study for AFP, CEA, CA19-9, CA125, and PSA included outpatients in Asan Medical Center from February to March, 2009. The standard value was obtained by using the percentage of CV of Inter Assay according to the normal range of each tumor test. The results were confirmed by using the OCS QC program via formatted assessment of screening test such as test items, standard value and medical department. The number of out-of-range results within plus and minus 30 percents regarding the five primary items of tumor marker test was assessed. The next step was to obtain the number of AFP, CEA, and CA125 according to the ratio of comparison between prior and post test result, 60%, 50%, and 40% within normal range, respectively. In addition, set standard value below normal range. Results: The first screening test with percentage of sample number was resulted between 30%-40% and the second one was AFP 26.1%, CEA 18.9%, CA19-9 17.3%, CA125 18.7%, and PSA 21.0% obtained screening percentage of average 20 percents. The limited value of retest was AFP less than 5.0 and more than 10.0, CEA less than 1.0 and more than 3.0, CA19-9 less than 10.0 and more than 30.0, and PSA less than 1.0 and more than 2.0 to set and the number of retest was obtained by applying to the limited value of retest to screening percentage of average 20 percents For two months, the number of retest was AFP 0, CEA 15, CA19-9 3, CA125 2, and PSA 5. Conclusions: Through using the OCS QC program in establishing the standard of retest systemically, there appeared to be reduced discrepancy among the examiners and to be expected improvement in relation to the error of results.

목차

서론
대상 및 방법
결과
고찰
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

백송란(Song Ran Back),김성호(Sung ho Kim),유소연(So Yeon Yoo),김년옥(Nyun Ok Kim),문형호(Hyoung ho Moon),유선희(Seon Hee Yoo),조시만(Shee Man Cho). (2009).OCS QC 프로그램을 통한 건진 센터 종양검사의 결과보고 개선. 핵의학기술, 13 (2), 185-188

MLA

백송란(Song Ran Back),김성호(Sung ho Kim),유소연(So Yeon Yoo),김년옥(Nyun Ok Kim),문형호(Hyoung ho Moon),유선희(Seon Hee Yoo),조시만(Shee Man Cho). "OCS QC 프로그램을 통한 건진 센터 종양검사의 결과보고 개선." 핵의학기술, 13.2(2009): 185-188

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제