학술논문
Oncoflash를 적용한 전신 뼈 영상 검사의 스캔 속도 결정에 관한 연구
이용수 2
- 영문명
- A Study on the Determination of Scan Speed in Whole Body Bone Scan Applying Oncoflash
- 발행기관
- 대한핵의학기술학회
- 저자명
- 양광길(Gwang Gil Yang) 정우영(Woo Young Jung)
- 간행물 정보
- 『핵의학기술』Vol.13 No.2, 56~60쪽, 전체 5쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2009.10.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose: The various studies and efforts to develop program are in progress in the field of nuclear medicine for the purpose of reducing scan time. The Oncoflash is one of the programs used in whole body bone scan which allows to maintain the image quality while to reduce scan time. When Those applications are used in clinical setting, both the image quality and reduction of scan time should be considered, therefore, the purpose of this study was to determine the criteria for proper scan speed. Materials and Methods: The subjects of this study were the patients who underwent whole body bone scan at the departments of nuclear medicine in the Asan Medical Center located in Seoul from 1st to 10th, July, 2008. The whole body bone images obtained in the scan speed of 30cm/min were classified by the total counts into under 800 K, and over 800 K, 900 K, 1,000 K, 1,500 K, and 2,000 K. The image quality were assessed qualitatively and the percentages of those of 1,000K and under of total counts were calculated. The FWHM before and after applying the Oncoflash were analyzed using images obtained in ⁹⁹ᵐTc Flood and 4-Quadrant bar phantom in order to compare the resolution according to the amount of total counts by the application of the Oncoflash. Considering the counts of the whole body bone scan, the dosed 2~5 mCi were used. 152 patients underwent the measurement in which the counts of Patient Postioning Monitor (PPM) were measured with including head and the parts of chest which the starting point of whole body bone scan from 7th to 26th, August, 2008. The correlations with total counts obtained in the scan speed of 30cm/min among them were analyzed (The exclusion criteria were after over six hours of applying isotopes or low amount of doses). Results: The percentage of the whole body bone image which has the geometric average of total counts of under 1,000K among them obtained in the scan speed of 30cm/min were 17.6%(n=58) of 329 patients. The qualitative analysis of the image groups according to the whole body counts showed that the images of under 1,000K were assessed to have coarse particles and increased noises. The analysis on the FWHM of the images before and after applying the Oncoflash showed that, in the case of PPM counts of under 3.6 K, FWHM values after applying the Oncoflash were higher than that before applying the Oncoflash, whereas, in the case of that of over 3.6 K, the FWHM after applying the Oncoflash were not higher than that before applying the Oncoflash. The average of total counts at 2.5~3.0 K, 3.1~3.5 K, 3.6~4.0 k, 4.1~4.5 K, 4.6~5.0 K, 5.1~6.0 K, 6.1~7.0 K, and 7.1 K over (in PPM) were 965±173 K, 1084±154 K, 1242±186 K, 1359±170 K, 1405±184 K, 1640±376K, 1,771±324 K, and 1,972±385 K, respectively and the correlations between the counts in PPM and the total counts of image obtained in the scan speed of 30 cm/min demonstrated strong correlation (r=.775, p<.01). Conclusions: In the case of PPM coefficient over 3.6 K, the image quality obtained in the scan speed of 30cm/min and after applying the Oncoflash was similar to that obtained in the scan speed of 15 cm/min. In the case of total counts over 1,000 K, it is expected to reduce scan time without any damage on the image quality. In the case of total counts under 1,000 K, however, the image quality were decreased even though the Oncoflash is applied, so it is recommended to perform the re-image in the scan speed of 15 cm/min.
목차
서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES
해당간행물 수록 논문
- PET/CT 검사 환자의 피폭선량 경감을 위한 연구
- PET/CT 에서 표준섭취계수(SUV)의 신뢰성 확보를 위한 초기연구
- Oncoflash를 적용한 전신 뼈 영상 검사의 스캔 속도 결정에 관한 연구
- 진단 검사의학과와 중복되는 검사들의 결과 비교, 분석(TSH, FT₄, AFP, CEA, PSA)
- 미만성 남궁혁거대 B 세포 림프종 환자에서 Filgrastim 사용이 PET/CT 영상에 미치는 영향에 대한 고찰
- 핵의학과 종사자의 방사성동위원소 체내오염 측정
- 스캔 시간의 결정시기에 따른 총 스캔 시간 변화에 관한 연구
- 측정법에 따른 갑상선자극호르몬 결합억제면역글로블린(TBII)의 임상적 유용성 검토
- 자동분주기의 이월오염 평가
- ²⁰¹Tl 게이트 심근관류 스펙트에서의 휴식기와 부하기 좌심실 구혈률 상관관계 분석
- 월경주기에 따른 18F-FDG PET/CT의 자궁 내 섭취에 관한 연구
- ¹³¹I 3700 MBq (100 mCi) Therapy 입원 환자의 선량률(μSv/h), 잔류량(mCi), 배설률(%) 측정
- LAL Test에서 위양성을 나타내는 원인들에 대한 고찰
- Tl-201 심근 관류 SPECT에서 4DM, QPS, ECT 프로그램의 정량적 지표 비교 분석
- 전신 영상 검사 시행 시 테이블 이동속도의 정확성에 관한 연구
- Flash 3D 재구성을 적용한 뇌 혈류 부하 단층 촬영 시 LEAP 검출기의 적용에 관한 연구
- 핵의학과 내에서의 효과적인 고객위험관리
- 골절의 절대위험도 평가방법에서 GE Prodigy와 FRAX Tool의 비교분석에 관한 고찰
- Cortisol, 25OHD₃ 추출 후 원심 분리시 온도가 검사결과에 미치는 영향
- 핵의학 혈액 검사의 경고치 자동통보 시스템
- 검체 문의에 관한 문제점 및 개선방안
- 자동 분주기 Fixed Tip의 Carryover 방지를 위한 개선 방안
- 유방암 환자에서 Breast Specific Gamma Imaging (BSGI)의 유용성
- Gates 방법과 혈청 크레아티닌을 이용한 사구체 여과율의 비교
- 부갑상선 신티그라피를 시행한 환자들의 병소 국소화에 따른 후향적 분석연구
- 갑상선암에서의 혈중 Thyroglobulin 농도와 침생검 검체 Washout Solution의 Thyroglobulin 농도와의 상관관계
- 비소세포성폐암 환자의 Monototal™ 유용성 평가
- OCS QC 프로그램을 통한 건진 센터 종양검사의 결과보고 개선
- 전립선암 환자의 뼈 전이에 대한 ¹⁸F-Fluoride PET/CT의 유용성
- FRAX Tool에서 골절위험인자에 따른 골절위험도의 변화
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- Attention UNet 모델을 활용한 유방 초음파 영상 분할: IoU 기반 학습 및 AUC, MSE 평가
- RI 등 사용 허가 대학의 정기 검사 수검 사례: 방사선학과를 대상으로
- 삼중수소 측정 신뢰성 검증을 위한 국제숙련도시험 결과 평가
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!