본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

PET/CT 에서 표준섭취계수(SUV)의 신뢰성 확보를 위한 초기연구

이용수 0

영문명
An Initial Study on the Reliability Assurance in PET/CT Standardized Uptake Values
발행기관
대한핵의학기술학회
저자명
박훈희(Hoon Hee Park) 김정열(Jung Yul Kim) 이승재(Seung Jae Lee) 박민수(Min Soo Park) 남궁혁(Hyuk NamKoong) 임한상(Han Sang Lim) 오기백(Ki Baek Oh) 김재삼(Jae Sam Kim) 이창호(Chang Ho Lee) 진계환(Gye Hwan Jin)
간행물 정보
『핵의학기술』Vol.13 No.2, 31~42쪽, 전체 12쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2009.10.30
4,240

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: As the number of domestic medical institutions installing PET/CT is increasing rapidly, the transfer of PET/CT images among medical institutions is also increasing. Thus, it is necessary to collect the comparative SUV data from several medical institutions’ PET/CT systems through a phantom study which semiquantitatively compares the SUV on one bed, the change scale of the SUV on the slices, and the time of measuring. The phantom study to find differences among the SUVs from various PET/CT offers the opportunity to obtain the reliability of the SUV in PET/CT images. Materials and Methods: Ten PET/CT systems from medical institutions in Korea were used. To obtain the accurate data, the study has been using the radiation detector of Korea Research Institute of Standards and Science to verify. The internal structures of NEMA PET phantom TM were removed and Six thousand milliliters of distilled water which has 1mCi of 18F-FDG put into the phantom. The water was properly integrated with 18F-FDG using magnetic stirrer. The images were acquired at 60, 70, 80, 90, 100, 110 and 120-minutes for 3 minute each. Two hundred square centimeters of region of interests were placed and analyzed. To confirm the usefulness, the correction-table came out from patients’ data. Results: The coefficient of variability of the SUV from -11.0 to 9.90 % fell into the range of international standards(±10%) along with the SUV on a bed, the change scale of the SUV on the slices, and the time of measuring, except one PET/CT system. Using the data of the differences among the SUVs, we came to withdraw the correction-table ranging from 0.803 to 1.246. The correction-table was confirmed its usefulness through Linear Regression Analysis which was applied to normal cases. Conclusions: Although studies have been made on the variation of the SUV, there is little attention on the standardization of the SUV. Based on this study of the quantitatively comparable data about the SUV accommodating the correction-table, it would help to have more corrective diagnosis.

목차

INTRODUCTION
MATERIALS AND METHODS
RESULTS
CONCLUSIONS
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

박훈희(Hoon Hee Park),김정열(Jung Yul Kim),이승재(Seung Jae Lee),박민수(Min Soo Park),남궁혁(Hyuk NamKoong),임한상(Han Sang Lim),오기백(Ki Baek Oh),김재삼(Jae Sam Kim),이창호(Chang Ho Lee),진계환(Gye Hwan Jin). (2009).PET/CT 에서 표준섭취계수(SUV)의 신뢰성 확보를 위한 초기연구. 핵의학기술, 13 (2), 31-42

MLA

박훈희(Hoon Hee Park),김정열(Jung Yul Kim),이승재(Seung Jae Lee),박민수(Min Soo Park),남궁혁(Hyuk NamKoong),임한상(Han Sang Lim),오기백(Ki Baek Oh),김재삼(Jae Sam Kim),이창호(Chang Ho Lee),진계환(Gye Hwan Jin). "PET/CT 에서 표준섭취계수(SUV)의 신뢰성 확보를 위한 초기연구." 핵의학기술, 13.2(2009): 31-42

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제