PET/CT 검사 환자의 피폭선량 경감을 위한 연구

이용수 0

영문명
Research on the Reduction of Exposure Dose of a Patient Having a PET/CT Exam
발행기관
대한핵의학기술학회
저자명
김봉수(Bong Su Kim) 표성재(Sung Jai Pyo) 조용귀(Yong Gyi Cho) 신채호(Chai Ho Shin) 조진우(Jin Woo Cho) 김창호(Chang Ho Kim)
간행물 정보
『핵의학기술』Vol.13 No.2, 10~16쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2009.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: As the number of patients has increased since the installation of a PET/CT, we are now examining about 2500-3000 annually. We have realized that if we properly adjust a pitch under the same condition of a CT during a PET/CT exam, radiation quantity that reaches the patient can change. In order to reduce the exposure dose of a patient, the research examines a method of reducing the exposure dose of a patient by controlling the pitch during a PET/CT exam, viewing whether the adjustment of the pitch influences CT image and PET SUV. Methods: The equipment used is a Biograph Positron Emission Tomography (PET) Scanner (CT type: TRCT-240-130 (WCT-240-130)) of Siemens company. For the evaluation of exposure dose of a patient, we measured radiation quantities using a PTW-DIADOS 11003/1383, which is a CT radiation measurement instrument used by Siemens. We measured and analyzed the space resolutions of CT images caused by the change of pitches using an AAPM Standard Phantom in order to see how the adjustment of pitches influenced the CT images. In addition, in order to obtain SUVs caused by each change of pitches using a PET source made with a solid radioactive cylinder phantom, we confirmed whether the SUVs changed in the PET/CT images by calculating the SUVs of the fusion images caused by the change of pitches after obtaining CT and PET images and finishing the test. Results: 2slice CT scanner showed that radiation quantities largely dropped when pitches ranged from 0.7 to 1.3 and that the reduction of radiation quantities were smaller when pitches ranged from 1.5 to 1.9. That is, we found that the bigger pitch values are the smaller the radiation quantities of a patient are. Moreover, we realized that there is no change of SUVs caused by the increase of pitches and that pitch values do not influence PET SUVs and the quality of CT images. It is judged that using 1.5 as a pitch value contributes to the reduction of exposure dose of a patient as long as there is no problem in the quality of an image. Conclusions: When seeing the result of the research, hospital using a PET/CT should make an effort to reduce the exposure dose of a patient seeking pitch values appropriate for their hospital within the range in which there is no image distortion and PET SUVs are not influenced from pitches. We think that the research can apply to all multi-detectors having a CT scanner and that such a research will be needed for other equipments in the future.

목차

서론
실험재료 및 방법
결과
고찰
결론
요약
KNOWLEDGE
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김봉수(Bong Su Kim),표성재(Sung Jai Pyo),조용귀(Yong Gyi Cho),신채호(Chai Ho Shin),조진우(Jin Woo Cho),김창호(Chang Ho Kim). (2009).PET/CT 검사 환자의 피폭선량 경감을 위한 연구. 핵의학기술, 13 (2), 10-16

MLA

김봉수(Bong Su Kim),표성재(Sung Jai Pyo),조용귀(Yong Gyi Cho),신채호(Chai Ho Shin),조진우(Jin Woo Cho),김창호(Chang Ho Kim). "PET/CT 검사 환자의 피폭선량 경감을 위한 연구." 핵의학기술, 13.2(2009): 10-16

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제