학술논문
Tl-201 심근 관류 SPECT에서 4DM, QPS, ECT 프로그램의 정량적 지표 비교 분석
이용수 2
- 영문명
- Analysis of Quantitative Indices in Tl-201 Myocardial Perfusion SPECT: Comparison of 4DM, QPS, and ECT Program
- 발행기관
- 대한핵의학기술학회
- 저자명
- 이동훈(Dong Hun Lee) 심동오(Dong Oh Shim) 유희재(Hee Jae Yoo)
- 간행물 정보
- 『핵의학기술』Vol.13 No.2, 67~75쪽, 전체 9쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2009.10.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose: As to the analytical method of data, the various programs in which it is used for the quantitative rating of the Tl-201 myocardial perfusion SPECT are reported that there is a difference. Therefore, the measured value error of the mutual program is expected to be generated even if the quantitative analysis is made against data of the same patient. Using quantitative index that able to represent myocardial perfusion defect level, we aimed to determine correlation among three myocardial perfusion analysis programs 4DM (4DMSPECT), QPS (Quantitative Perfusion SPECT), ECT (Emory Cardiac Toolbox) that be used generally in most departments of Nuclear Medicine. Materials and Methods: We analyzed the 145 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Mediacal Center from December 1th 2008 to February 14th 2008. We sorted as normal group and abnormal group. Normal group consist of 80 patients (Male/Female=38/42, age:65.1±9.9) who have low possibility of cardiovascular disease. And abnormal group consist of 65 patients (Male/Female=45/20, age:63.0±8.7) who were diagnosed cardiovascular disease with reversible perfusion defect or fixed perfusion defect through myocardial perfusion SPECT results. Using the 4DM, QPS, and ECT programs, the total defect extent (TDE) such as LAD, LCX, RCA and the summed stress score (SSS) have been analysed for their correlations and statistical comparison with the paried t-test for the quantitative indices analysed from each group. Results: The correlation of 4DM:QPS, QPS:ECT, ECT:4DM each group result from 145 patients is 0.84, 0.86, 0.82 at SSS, 0.87, 0.84, 0.87 at TDE, and both index showed good correlation. In paired t-test and Bland-Altman analysis results showed no statistically significant difference in the comparison of QPS:ECT at the mean SSS and TDE, 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index. The correlation of 4DM:QPS, QPS:ECT, ECT:4DM program results from abnormal group (65 patients) is 0.72, 0.72, 0.70 at SSS and 0.77, 0.70, 0.77 at TDE and TDE and SSS has a good correlation. In abnormal group, paired t-test and Bland-Altman analysis results showed no statistically significant difference at QPS:ECT SSS (p=0.89) and TDE (p=0.23) comparison, 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index (p<0.01). In normal group (80 patients) , paired t-test and Bland-Altman analysis results showed no statistically significant difference at QPS:ECT SSS (p=0.95) and TDE (p=0.73) comparison. And 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index (p<0.01). Conclusions: The perfusion defect of the Tl-201 myocardial perfusion SPECT was analyzed in not only the patient in whom it has the cardiovascular disease but also the patient in whom the possibility of the cardiovascular disease is few. In the comparison of the all group research, the mean of the TDE and SSS, 4DM was lower than QPS and ECT progrms. Each program showed good correlation and the results showed statistically significant difference. However, in this way, it is determined to be compatible about the analysis value in which the large-scale side between the programs uses each program a difference in a clinical in the Bland-Altman analyzed result in spite of the good correlation and cannot use. but, this analyzed result will be able to be usefully used as the reference material for the clinical read and is expected.
목차
서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES
해당간행물 수록 논문
- PET/CT 검사 환자의 피폭선량 경감을 위한 연구
- PET/CT 에서 표준섭취계수(SUV)의 신뢰성 확보를 위한 초기연구
- Oncoflash를 적용한 전신 뼈 영상 검사의 스캔 속도 결정에 관한 연구
- 진단 검사의학과와 중복되는 검사들의 결과 비교, 분석(TSH, FT₄, AFP, CEA, PSA)
- 미만성 남궁혁거대 B 세포 림프종 환자에서 Filgrastim 사용이 PET/CT 영상에 미치는 영향에 대한 고찰
- 핵의학과 종사자의 방사성동위원소 체내오염 측정
- 스캔 시간의 결정시기에 따른 총 스캔 시간 변화에 관한 연구
- 측정법에 따른 갑상선자극호르몬 결합억제면역글로블린(TBII)의 임상적 유용성 검토
- 자동분주기의 이월오염 평가
- ²⁰¹Tl 게이트 심근관류 스펙트에서의 휴식기와 부하기 좌심실 구혈률 상관관계 분석
- 월경주기에 따른 18F-FDG PET/CT의 자궁 내 섭취에 관한 연구
- ¹³¹I 3700 MBq (100 mCi) Therapy 입원 환자의 선량률(μSv/h), 잔류량(mCi), 배설률(%) 측정
- LAL Test에서 위양성을 나타내는 원인들에 대한 고찰
- Tl-201 심근 관류 SPECT에서 4DM, QPS, ECT 프로그램의 정량적 지표 비교 분석
- 전신 영상 검사 시행 시 테이블 이동속도의 정확성에 관한 연구
- Flash 3D 재구성을 적용한 뇌 혈류 부하 단층 촬영 시 LEAP 검출기의 적용에 관한 연구
- 핵의학과 내에서의 효과적인 고객위험관리
- 골절의 절대위험도 평가방법에서 GE Prodigy와 FRAX Tool의 비교분석에 관한 고찰
- Cortisol, 25OHD₃ 추출 후 원심 분리시 온도가 검사결과에 미치는 영향
- 핵의학 혈액 검사의 경고치 자동통보 시스템
- 검체 문의에 관한 문제점 및 개선방안
- 자동 분주기 Fixed Tip의 Carryover 방지를 위한 개선 방안
- 유방암 환자에서 Breast Specific Gamma Imaging (BSGI)의 유용성
- Gates 방법과 혈청 크레아티닌을 이용한 사구체 여과율의 비교
- 부갑상선 신티그라피를 시행한 환자들의 병소 국소화에 따른 후향적 분석연구
- 갑상선암에서의 혈중 Thyroglobulin 농도와 침생검 검체 Washout Solution의 Thyroglobulin 농도와의 상관관계
- 비소세포성폐암 환자의 Monototal™ 유용성 평가
- OCS QC 프로그램을 통한 건진 센터 종양검사의 결과보고 개선
- 전립선암 환자의 뼈 전이에 대한 ¹⁸F-Fluoride PET/CT의 유용성
- FRAX Tool에서 골절위험인자에 따른 골절위험도의 변화
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- Attention UNet 모델을 활용한 유방 초음파 영상 분할: IoU 기반 학습 및 AUC, MSE 평가
- RI 등 사용 허가 대학의 정기 검사 수검 사례: 방사선학과를 대상으로
- 삼중수소 측정 신뢰성 검증을 위한 국제숙련도시험 결과 평가
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)