본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

²⁰¹Tl 게이트 심근관류 스펙트에서의 휴식기와 부하기 좌심실 구혈률 상관관계 분석

이용수 0

영문명
The Correlation Analysis of Stress/Rest Ejection Fraction of ²⁰¹Tl Gated Myocardial Perfusion SPECT
발행기관
대한핵의학기술학회
저자명
김동석(Dong Seok Kim) 유희재(Hee Jae Yoo) 심동오(Dong Oh Shim)
간행물 정보
『핵의학기술』Vol.13 No.2, 3~9쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2009.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: It is well-known that stress-induced stunning and reversible perfusion defect have impact on ejection fraction (EF) when performing myocardial perfusion SPECT. Due to these reasons, gated SPECT is recommended at stress and rest studies. And there was many experiments to analyze between Stress and Rest EF by using ⁹⁹ᵐTc-MIBI. The aim of this study is to analyze between stress EF and rest EF at myocardial perfusion SPECT by using ²⁰¹Tl and define possible predictors of EF variability. Materials and Methods: From 2008 June to 2009 February, we analyzed 144 patients undergoing ²⁰¹Tl gated myocardial perfusion SPECT in ASAN medical center. To analyze the data, we use QGS (Quantitative gated SPECT) software, and derived End-systolic volume (ESV), End-diastolic volume (EDV), EF from the result. In this study, we comparatively analyzed stress/rest EF correlation based on stress/rest EF, EDV, ESV and reversibility of myocardial perfusion defect by using paired t-test, Bland-Altman analysis. Results: Mached pairs of stress EF and rest EF demonstrated excellent correlation (r=0.92) with no statistically significant difference (p=0.11). Bland-Altman analysis demonstrated a mean ΔEF was 0.52% (95% confidential interval[CI], -1.17~0.12%). No statistically significant difference between a mean ΔEF and hypothetic mean of 0 (ΔEF=0) (p=0.10). In the correlation of ΔEF according to stress/rest EDV and ESV, except rest ESV of <28mL (p<0.05), there was no statistically significant difference. In the correlation of ΔEF according to reversibility of perfusion defect, patients with reversible perfusion defect has statistically significant difference of ΔEF (p<0.05). ΔEF of stress/rest EF showed no statistically significant difference except 55% of rest EF (p<0.05). Conclusion: Like studies with ⁹⁹ᵐTc-MIBI, there was generally no statistically significant difference between stress and rest EF in this study results. However a stress EF of <55%, a rest ESV of <28mL and patients with reversible perfusion defect showed statistically significant difference in ΔEF. If performing ²⁰¹T myocardial perfusion SPECT to patients with abnormal cardiac function or reversible perfusion defect, consider this study results and apply it. We expect this study results could be useful predictors of ΔEF variability.

목차

서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김동석(Dong Seok Kim),유희재(Hee Jae Yoo),심동오(Dong Oh Shim). (2009).²⁰¹Tl 게이트 심근관류 스펙트에서의 휴식기와 부하기 좌심실 구혈률 상관관계 분석. 핵의학기술, 13 (2), 3-9

MLA

김동석(Dong Seok Kim),유희재(Hee Jae Yoo),심동오(Dong Oh Shim). "²⁰¹Tl 게이트 심근관류 스펙트에서의 휴식기와 부하기 좌심실 구혈률 상관관계 분석." 핵의학기술, 13.2(2009): 3-9

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제