Purpose: The automatic notification system for alarm values on blood tests conducted by this hospital is designed to immediately inform the attending physician of the result of a blood test, to help the relevant patient to promptly receive proper treatment, and furthermore, to reduce the likelihood of a fatal influence to the patient. From 2004, the clinical pathology department of this hospital has been operating an automatic notification system for blood tests, in relation to the items of WBC, Hb, Plt, PB cell morphology, Malaria, PT, aPTT, BT, fibrinogen, Ca, K, Na, Cl, Mg, Glucose, Ketone, Digoxin, PKU, Homocystinuria, 17-OHP, Neonatal TSH, and Galactosemia. Recently, the blood test room of the nuclear medicine department has been operating an automatic notification system for the alarm values of a blood test, in relation to three items of TSH, FT4, and 17- α-OH-PGR, and the details of its operation will be described here. Materials and Methods: The subjects were newborn babies that were receiving TSH, FT4, and 17α-OH-PGR prescriptions from February 19th to May 11st, 2009, and who met with the following criteria: N2340 Thyroid-Stimulating Hormone: >10μIU/mL (Reference value: 0.4~5.0). N2360 Free-Thyroxine: <0.8μg/dL (Reference value: 0.8~1.9), N2444 17α-OH-Progesterone: >30 μg/mL (Reference value: Male (0.6~3.42), Female follicular phase (0.19~1.8). The automatic notification system was operated by entering test items, relevant treatment departments, and standard values for reporting alarm values into the OCS program, and then transmitting results that met with the input conditions to the PDAs of the prescription and the attending physician by SMS. Results: Reporting an alarm value of the nuclear medicine blood test, which can have a fatal influence on the lives of patients, will help cure patients, improve the quality of the test, and furthermore, will increase the patient’s satisfaction with the prescription and treatment of the test.

목차

서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

심성재(Seong Jae Sim),윤필영(Pil Young Yoon),임수연(Soo Yeon Lim),천준홍(Jun Hong Cheon),신영균(Young Kyoon Shin),유선희,조시만(Si Man Cho). (2009).핵의학 혈액 검사의 경고치 자동통보 시스템. 핵의학기술, 13 (2), 159-164

MLA

심성재(Seong Jae Sim),윤필영(Pil Young Yoon),임수연(Soo Yeon Lim),천준홍(Jun Hong Cheon),신영균(Young Kyoon Shin),유선희,조시만(Si Man Cho). "핵의학 혈액 검사의 경고치 자동통보 시스템." 핵의학기술, 13.2(2009): 159-164

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제