본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

인증표준물질(CRM)을 이용한 방사면역측정법의 회수율 평가

이용수 0

영문명
The Evaluation of Recovery Rate of Radioimmunoassay Using Certified Reference Material (CRM)
발행기관
대한핵의학기술학회
저자명
최성희(Sung Hee Choi) 신선영(Sun Young Shin) 임소희(So Hee Lim) 홍미경(Mee Kyung Hong) 노경운(Gyeong Woon Noh) 김진의(Jin Eui Kim)
간행물 정보
『핵의학기술』Vol.18 No.1, 158~162쪽, 전체 5쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2014.05.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: Reference material (RM) is defined as material that is safe and homogeneous enough about specified characteristic that is made with a purpose of using test of measurement or nominal characteristic. Certified reference material (CRM), which is issued by authorized organization, is defined as reference material that provides characteristic value, link uncertainty and retroactivity. The purpose of this paper was to evaluate recovery of radioimmunoassay by Certified Reference Material enclosed with a certificate and therefore to enhance reliability of test. Materials and Methods: WHO certified reference material is purchased from NIBSC (National Institute for Biological Standard and Control, United Kingdom) and made of 3 levels that are C-1 (low concentration), C-2 (medium concentration) and C-3 (high concentration) and measured for kit at the Seoul National University Hospital. Recovery rate is evaluated after measurement at four different days. Results: Recovery rate results using WHO certified reference material are T4 90%, Ferritin 88%, PSA 94%, Prolactin 99%, AFP 94% and TSH 93%. Conclusion: A procedure that appropriate accuracy, precision, specificity, sensitivity, reproducibility, and validate on the subject of kit for radioimmunoassay is essential. Recovery rate assay as extraction efficiency of analysis process is percent about already measuring results of analysis result after all measuring process. This is very important assessment standards of performance evaluation of immunoassay kit. Recovery rate results of 6 type used WHO CRM are satisfactory to 88~99%. This demonstrates that the radioimmunoassay is a very accurate measurement, which is very effectively utilized in clinical practice.

목차

INTRODUCTION
MATERIALS AND METHODS
Results
Discussion and Conclusion
SUMMARY
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

최성희(Sung Hee Choi),신선영(Sun Young Shin),임소희(So Hee Lim),홍미경(Mee Kyung Hong),노경운(Gyeong Woon Noh),김진의(Jin Eui Kim). (2014).인증표준물질(CRM)을 이용한 방사면역측정법의 회수율 평가. 핵의학기술, 18 (1), 158-162

MLA

최성희(Sung Hee Choi),신선영(Sun Young Shin),임소희(So Hee Lim),홍미경(Mee Kyung Hong),노경운(Gyeong Woon Noh),김진의(Jin Eui Kim). "인증표준물질(CRM)을 이용한 방사면역측정법의 회수율 평가." 핵의학기술, 18.1(2014): 158-162

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제