본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

핵의학 영상검사 후 시행된 핵의학 검체검사에서의 영향

이용수 0

영문명
The Effect on The Result, in Case of the In-vitro Test Performance after an Imaging Test
발행기관
대한핵의학기술학회
저자명
문기춘(Ki Choon Moon) 권원현(Won Hyun Kwon) 김정인(Jung In Kim) 이인원(In Won Lee)
간행물 정보
『핵의학기술』Vol.18 No.1, 149~152쪽, 전체 4쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2014.05.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: At our hospital blood is collected from a patient before an imaging test, with the concern of any effect possible when a nuclear medicine imaging test and an in-vitro test are carried out at the same time. However, occasionally, the blood collection is performed after an imaging test, with the reasons that the patient is not properly guided or the patient doesn't follow the guide correctly. In that case, we prefer to gather blood again after a few days. The purpose of this study is not only to see whether there is any effect of an imaging test on the result of the in-vitro test performed with the blood collected after the imaging test, but also to study how many days waiting after each test is appropriate to take a blood sample, if the effect exists. Materials and Methods: From September to October 2013, blood were collected from 13 patients in our hospital regardless of age and sex each time before and after the injection of the radioactive isotope from the tests : PET-CT, Gated Myocardial SPECT, and DTPA GFR Scan. Considering a half-life, AFP, CA19-9, CEA, TSH, and T3 were carried out right after the blood collection. In case of an iodine therapy, blood were taken each time before and after taking radioactive iodine, and, after AFP, CA19-9, and CEA, the difference between them in consistency and in cpm were compared. Results: With 10 patients after the imaging tests and 3 patients after the iodine therapy, their serum cpm was over 10,000. Over time, the cpm decreased in accordance with the half-life (¹⁸F 110minutes, ⁹⁹ᵐTc 6hours, ²⁰¹Tl 72hours, ¹³¹I 7days). Between the two cases, one before and the other after the injection of the radioactive isotope, the cpm and the results of AFP, CA19-9, CEA, TSH, and T3 from three patients each test, PET-CT, Gated Myocardial SPECT, and DTPA GFR Scan, were very similar. In addition, in case of an iodine therapy, there was also not a meaningful difference in the cpm and the results of AFP, CA19-9, and CEA, from three patients in an iodine therapy, between the two cases, one before and the other after taking the radioactive iodine. Conclusion: In case a blood collection was performed after the imaging test which required a radioactive isotope injection, the cpm increased, differently according to the kind of the radioactive isotope. However, the results of the in-vitro tests like AFP, CA19-9, CEA, TSH, T3, etc were nearly not affected. As the result, it's considered that there will not be any significant effect also from other tests, as the result from the performed seven tests.

목차

서론
대상 및 방법
결과
결론 및 고찰
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

문기춘(Ki Choon Moon),권원현(Won Hyun Kwon),김정인(Jung In Kim),이인원(In Won Lee). (2014).핵의학 영상검사 후 시행된 핵의학 검체검사에서의 영향. 핵의학기술, 18 (1), 149-152

MLA

문기춘(Ki Choon Moon),권원현(Won Hyun Kwon),김정인(Jung In Kim),이인원(In Won Lee). "핵의학 영상검사 후 시행된 핵의학 검체검사에서의 영향." 핵의학기술, 18.1(2014): 149-152

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제