I-131 SPECT/CT 검사의 에서 조준기 종류에 따른 영상 비교 평가

이용수 0

영문명
Comparison of Collimator Choice on Image Quality of I-131 in SPECT/CT
발행기관
대한핵의학기술학회
저자명
김정열(Jung Yul Kim) 김주연(Joo Yeon Kim) 남궁혁(Hyuk Nam-Koong) 강천구(Chun Goo Kang) 김재삼(Jae Sam Kim)
간행물 정보
『핵의학기술』Vol.18 No.1, 33~42쪽, 전체 10쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2014.05.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: I-131 scan using High Energy (HE) collimator is generally used. While, Medium Energy (ME) collimator is not suggested to use in result of an excessive septal penetration effects, it is used to improve the sensitivities of count rate on lower dose of I-131. This research aims to evaluate I-131 SPECT/CT image quality using by HE and ME collimator and also find out the possibility of ME collimator clinical application. Materials and Methods: ME and HE collimator are substituted as Siemens symbia T16 SPECT/CT, using I-131 point source and NEMA NU-2 IQ phantom. Single Energy Window (SEW) and Triple Energy Windows (TEW) are applied for image acquisition and images with CTAC and Scatter correction application or not, applied different number of iteration and sub set are reconstructed by IR method, flash 3D. By analysis of acquired image, the comparison on sensitivities, contrast, noise and aspect ratio of two collimators are able to be evaluated. Results: ME Collimator is ahead of HE collimator in terms of sensitivity (ME collimator: 188.18 cps/MBq, HE collimator: 46.31 cps/MBq). For contrast, reconstruction image used by HE collimator with TEW, 16 subset 8 iteration applied CTAC is shown the highest contrast (TCQI=190.64). In same condition, ME collimator has lower contrast than HE collimator (TCQI=66.05). The lowest aspect ratio for ME collimator and HE collimator are 1.065 with SEW, CTAC (+) and 1.024 with TEW, CTAC (+) respectively. Conclusion: Selecting a proper collimator is important factor for image quality. This research finding tells that HE collimator, which is generally used for I-131 scan emitted high energy γ-ray is the most recommendable collimator for image quality. However, ME collimator is also applicable in condition of lower dose, lower sensitive if utilizing energy window, matrix size, IR parameter, CTAC and scatter correction appropriately.

목차

서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김정열(Jung Yul Kim),김주연(Joo Yeon Kim),남궁혁(Hyuk Nam-Koong),강천구(Chun Goo Kang),김재삼(Jae Sam Kim). (2014).I-131 SPECT/CT 검사의 에서 조준기 종류에 따른 영상 비교 평가. 핵의학기술, 18 (1), 33-42

MLA

김정열(Jung Yul Kim),김주연(Joo Yeon Kim),남궁혁(Hyuk Nam-Koong),강천구(Chun Goo Kang),김재삼(Jae Sam Kim). "I-131 SPECT/CT 검사의 에서 조준기 종류에 따른 영상 비교 평가." 핵의학기술, 18.1(2014): 33-42

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제