본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Adaptive Statistical Iterative Reconstruction 기법을 이용한 Bone SPECT/CT 검사에서 피폭량 감소 방안

이용수 0

영문명
Reducing Dose in SPECT/CT Using Adaptive Statistical Iterative Reconstruction Technique
발행기관
대한핵의학기술학회
저자명
최진욱(Jin-Wook Choi) 최현준(Hyeon-Jun Choi) 박찬록(Chan-Rok Park) 조성욱(Sung-Wook Cho) 김진의(Jin-Eui Kim) 이재성(Jae-Sung Lee) 이동수(Dong-Soo Lee)
간행물 정보
『핵의학기술』Vol.18 No.1, 134~139쪽, 전체 6쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2014.05.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: Adaptive statistical iterative reconstruction (ASIR) technique is a reconstruction method of CT image using statistical noise modeling which is known to reduce image noise and to preserve image quality despite reducing radiation dose. The aim of this study is to evaluate images using ASIR on bone SPECT/CT which is primarily performed in our hospital. Materials and Methods: We compared the images of applied ASIR (ASIR level: 20-80%) and none ASIR by changing the mA based on 120 kVp, 100 mA using Discovery NM/CT 670 (GE, U.S.A). First, we evaluated attenuation correction in SPECT image by changing the ASIR level using Anthropomorphic phantom. Second, we compared the contrast to noise ratio (CNR), image noise and spatial resolution in CT image using ACR phantom. Third, after selecting the ASIR level applicable patient using lower torso phantom, we examined 2 patients who followed up bone SPECT/CT and we performed blind test. Results: The degree of attenuation correction in SPECT image showed no significant difference between applied ASIR and none ASIR (P>0.05). When applied ASIR, the noise of CT image were reduced at least 17 up to 52% by changing the mA. The CNR of image with ASIR was maintained more than 0.8 at 40 mA (ASIR 60%) while those without ASIR showed 0.42 at standard 40 mA. In comparison of the high contrast object, we distinguished 12 line pairs/cm at 40 mA regardless of appling ASIR. Comparison of the patients image applied ASIR level 60% (40 mA) which found out by spine image of lower torso phantom showed no signigicant difference between applied ASIR and none ASIR in blind test. The CTDIvol and DLP for applied ASIR 60% showed decreased by 60%, 60% on average than using standard mA. Conclusion: The study show that the radiation dose in SPECT/CT using ASIR can be reduced despite degradation of SPECT and CT images. In addition, higher ASIR level could be possibly applied characteristics of SPECT/CT that region of interest is limited to bone.

목차

서론
실험재료 및 방법
결과
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

최진욱(Jin-Wook Choi),최현준(Hyeon-Jun Choi),박찬록(Chan-Rok Park),조성욱(Sung-Wook Cho),김진의(Jin-Eui Kim),이재성(Jae-Sung Lee),이동수(Dong-Soo Lee). (2014).Adaptive Statistical Iterative Reconstruction 기법을 이용한 Bone SPECT/CT 검사에서 피폭량 감소 방안. 핵의학기술, 18 (1), 134-139

MLA

최진욱(Jin-Wook Choi),최현준(Hyeon-Jun Choi),박찬록(Chan-Rok Park),조성욱(Sung-Wook Cho),김진의(Jin-Eui Kim),이재성(Jae-Sung Lee),이동수(Dong-Soo Lee). "Adaptive Statistical Iterative Reconstruction 기법을 이용한 Bone SPECT/CT 검사에서 피폭량 감소 방안." 핵의학기술, 18.1(2014): 134-139

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제