학술논문
전산화 단층촬영에 사용되는 조영제의 부작용 발생에 대한 분석
이용수 49
- 영문명
- Analysis of adverse reaction of contrast medium used in Computed Tomography
- 발행기관
- 대한CT영상기술학회
- 저자명
- 임상묵(Sang Muk Lim) 조영기(Young Ki Cho) 구양수(Yang Soo Gu) 이강우(Kang Woo Lee) 송환수(Hwan Soo Song) 강화원(Hwa Won Kang) 김영빈(Young Bin Kim) 임성훈(Sung Hoon Lim) 온상구(Sang Gu On)
- 간행물 정보
- 『대한CT영상기술학회지』대한전산화단층기술학회지 제10권 제1호, 143~151쪽, 전체 9쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2008.04.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose
The objective of this article is to analyze the symptom of patients suffering the adverse reaction of contrast medium in CT test and the risk factor mat can cause adverse reaction in order to provide basic materials which contribute to find the method to reduce adverse reaction in advance.
Materials and Methods
Among the patients visiting university hospital from January to July, 2007, adults over 16 years old to whom contrast medium was applied into vein for CT test were chosen. Then, among them, 92 male and female patients who suffered the adverse reaction of contrast medium were selected as target. Analyzing backwardly the general property of testee recorded in the written consent for test which was received from patients or custodian before CT test and the former history of the adverse reaction of contrast medium, existence/unexistence of disease and the disease, the test result of patients (hypertension, allergy, asthma, medication adverse reaction, kidney disease, diabetes, digestive organ, respiratory organ, circulatory organ, nerve, hematogenesis, lymph, thyroid gland and other unidentified disease), the authors investigated the relation with adverse reaction and analyzed the risk factor of adverse reaction as per tested part, types of contrast, infusion quantity, infusion velocity in accordance with contrast medium applied to the testee. Further, the symptom of adverse reaction was analyzed in each type. Namely, actual number and percentage was analyzed in the division of dermal sensory system, respiratory organ, digestive organ, nerve system, circulatory organ, ophthalmologic system and so on. To analyze the risk factor of adverse reaction of testee after CT test, Chi-square test and simple/multiple regression analysis was adopted to diverse variables so as to analyze significance by using SPSS 10.0 statistical program.
Results
1. In the general property, the division of sex was 36 men(39.1%) and 56 women (60.9%), showing no significant difference in the analysis of sex on the symptom of adverse reaction(p=0.132). In the aspect of age, those in 50~59 years old showed the highest rate of adverse reaction -29 persons (31.5%) and those under 19 years old showed the lowest rate of adverse reaction -1 person (1.1%). Thus, the age analysis in the symptom of adverse reaction also showed no statistically significant difference(p=0.204). The occurrence of adverse reaction in each part of body for test also showed no significant difference from the symptom of adverse reaction of contrast medium (p=0.137).
2. In the case of type of contrast medium (p=0.093), infusion quantity (p=0.279), infusion velocity (p=0.314), there was no statistically significant difference from the symptom of adverse re-action of contrast medium. In the product of A-1,54 persons (58.7%), 61 persons (66.3%) in 121-130cc, 37 persons (40.2%) in 2.6-3.0cc/sec, respectively showing the highest distribution, namely, the symptom of adverse reaction.
In the former history of the contrast medium, 10 out of 92 persons(10.9%) were analyzed, thereby showing statistically significant difference(p=0.003).
3. In the analysis of adverse reaction of contrast medium as per history of disease, 9 patients(11%) of hypertension showed urticaria and itching, ex 7), 16 patients (19.5%) of allergic asthma showed urticaria and itching, ex 17) and flush, ex 5), 4 patients of medication adverse reaction (5.2%) showed flush, dermal edema, dizziness, ex 3), 3 patients(3.9%) of kidney disease showed urticaria and itching, ex 5), 32 patients(41.6%) of digestive organ disease, the highest distribution showed itching and urticaria, ex 30), flush, ex 11), 1 patient(1.3%) of nerve system disease showed urticaria and itching, dizziness, ex 2), 6 patients(7.8%) of thyroid gland disease showed urticaria and itching, ex 6), dyspnea, ex 2). Thus, the symptom of adverse reaction of contrast medium as per history of disease showed statistically significant difference(p=
목차
Abstract
I. 서론
II. 대상 및 방법
III. 성적
IV. 고찰
참고문헌
해당간행물 수록 논문
- CT Mammography검사 시 자세변화에 따른 영상평가 및 적정선량에 관한 연구
- MDCT에 사용되는 조영제의 부작용 감소방안에 대한 고찰
- Effective mAs 적용 CT에서 Pitch Factor 변화에 따른 Image Quality의 비교
- 조영제 부작용 환자 등록 전산프로그램 및 조영제 부작용 표준진료지침개발 후 부작용사례분석
- MDCT를 이용한 복부 3-phase검사시 추적검사환자의 피폭선량 감소를 위한 Bolus triggering에 대한 고찰
- 검진센터를 방문한 성인에서 64-MDCT를 이용한 뇌동맥 관상동맥 질환의 발견율에 대한 고찰
- DS(Dual Source) CT를 이용한 심장검사 시 Pitch선택에 따른 영향 분석
- Dual Source CT에서 Coronary검사의 방사선량 비교분석
- Low Dose CT Colonography(LDCTC)를 이용한 Automatic Exposure Controll(AEC)와 Beam Collimation의 변화에 따른 유용성 평가와 Effective Dose의 평가치에 대한 연구
- MDCT을 이용한 Cardica CT 검사에서 ECG-pulsing기능의 사용 경험 및 고찰
- Cardiac CT에서 Dual injector의 Dual flow technique을 이용한 Contrast media의 Optimize admix rate에 관한 연구
- Dual flow 기법을 이용한 Triphasic injection의 유용성
- MDCT를 이용한 Head Angiography검사 시 Contrast Volume 감소에 관한 연구
- MDCT를 이용한 Neck Angiography검사 시 조영제량 감소에 따른 화질 향상에 관한 연구
- 상행대동맥의 조영증강시간에 영향을 주는 인자 관한 연구
- Coronary CT Angiography에서 Cardio ImageXact
- Low dose CT Virtual Colonography의 유용성 평가
- MDCT의 다양한 알고리즘과 관상동맥내 삽입된 스텐트 내경측정의 영향
- 나선형 CT와 16 Slice MDCT의 Brain과 Abdome 검사 시 산란선에 관한 연구
- 급성 장출혈 환자에서 MDCT의 유용성
- Cardiac CTA시 진단영역 확대를 위한 Heart rate에 따른 조영제 주입방법에 관한 연구
- CT 3차원 영상의 의료 수가의 추가적인 분리 적용의 필요성에 대한 제언
- CT 유도하 대동맥 주변 임파절 흡입과 생검에 대한 고찰
- 저선량 CT Guided Interventional Study의 유용성 평가
- Care Dose 4D를 이용한 흉부검사의 노출조건의 적정성 연구
- 전산화 단층촬영에 사용되는 조영제의 부작용 발생에 대한 분석
- 64VCT를 이용한 관상동맥 검사시 z-axis Automatic CT tube current modulation을 통한 방사선량 감소방안에 대한 연구
- 두개부와 흉부 CT 검사시 Bismuth 차폐재를 이용한 안구의 렌즈와 유방의 선량감소에 대한 평가
- Spiral CT에서 Interpolation이 선량증가에 미치는 영향에 관한 연구
- CT 검사 시 촬영조건에 따른 Image Quality와 Dose에 관한 연구
- Coronary Angio CT에서 심박동수에 의한 조영증강의 추이
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- CT contrast 검사 시 중심 정맥관을 이용한 조영제 사용에 대한 연구
- CT조영제 부작용 고위험군에 대한 전처치의 유용성
의약학 > 방사선과학분야 NEW
- 초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구
- 방사선에 대한 지식 및 인식도 연구
- 입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!