본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

64VCT를 이용한 관상동맥 검사시 z-axis Automatic CT tube current modulation을 통한 방사선량 감소방안에 대한 연구

이용수 0

영문명
A Study on the Reduction of Radiation Dose When Examining Coronary Artery through CT Tube Current Modulation Employing 64VCT
발행기관
대한CT영상기술학회
저자명
허재윤(Jae Yoon Huh) 범희남(Hee Nam Bhum) 정주방(Joo Bang Jung) 김창곤(Chang Gon Kim) 선종백(Jong Baek Sun)
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제10권 제1호, 41~45쪽, 전체 5쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2008.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose This study is intended to examine the reduction method without the decrease in the quality of image through automatic CT tube current modulation when examining coronary artery employing 64VCT. Materials and Methods The object is 200 coronary artery examination patients using 64VCT reorganized as Auto mA group and Manual mA group, with 100 patients in each group from March 29th, 2007 to 24th October, 2007. 125 men and 75 women were selected for this study, and the patients’ average age was 54.27±10.3, and their BMI was 23.7±2.7. 5 minutes prior to the examination a spray-type NTG was injected onto the patients. β-blocker was injected 1 hour before the examination for the patients with irregular heart beat, and it was adjusted at under 65bpm. Light Speed VCT from GE was used accompanied by the alignment of ECG. Time Bolus was checked first using Smart Prep, and the segment setup was made by Scan Parameter as Scan Type: Cardiac(Helical), Cardiac Mode: BPM 30-75. Manual mA was set at .35 sec rotation time, 40mm detector coverage, .625mm thickness, .2:1~.24:1 pitch, 120kyp, 650mA. Auto mA was fixed between 300-700mA, and the rest conditions are the same as Manual mA. Contrast media and saline solution were injected on ante-cubital vein before scanning using Time Bolus, at 4.0/15cc and 4.0/20cc on Ao. Peak Check, and on Cardiac Scan, contrast media(Ultravist 370) and saline solution were injected at 4.0/80cc and 5.5/50cc following the order. After scanning, image of coronary artery was reconstructed, SD and CTDIvol displaying on the exam monitor using Axial image was measured in groups, and Automatic mA and Manual mA groups were compared and assessed. Results The object was a total of 200 patients divided into 125 men and 75 women. Auto mA group’s values were SD34.29±9.5 and CTDIvol 75.15±19.2, and Manual mA group’s values were SD30.7±6.7 and CTDIvol 91.2±7.6. When compared, Radiation Dose was decreased by 18%. Conclusion When SD and CTDIvol were assessed in separate groups, there was not evident difference in the quality of in1age between Auto mA group and Manual mA group, but the radiation dose was decreased by 18% on Auto mA condition.

목차

Abstract
I. 서론
II. 대상과 방법
III. 결과
IV. 고찰
V. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

허재윤(Jae Yoon Huh),범희남(Hee Nam Bhum),정주방(Joo Bang Jung),김창곤(Chang Gon Kim),선종백(Jong Baek Sun). (2008).64VCT를 이용한 관상동맥 검사시 z-axis Automatic CT tube current modulation을 통한 방사선량 감소방안에 대한 연구. 대한CT영상기술학회지, 10 (1), 41-45

MLA

허재윤(Jae Yoon Huh),범희남(Hee Nam Bhum),정주방(Joo Bang Jung),김창곤(Chang Gon Kim),선종백(Jong Baek Sun). "64VCT를 이용한 관상동맥 검사시 z-axis Automatic CT tube current modulation을 통한 방사선량 감소방안에 대한 연구." 대한CT영상기술학회지, 10.1(2008): 41-45

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제