CT 검사 시 촬영조건에 따른 Image Quality와 Dose에 관한 연구

이용수 39

영문명
A Research on Image Quality and Dose according to Optimal Exposure factor in CT Examination
발행기관
대한CT영상기술학회
저자명
유흥준(Heung Joon Yoo) 권성옥(Seong Ohk Kwon)
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제10권 제1호, 7~14쪽, 전체 8쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2008.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose To provide an advice on the patient dosimetry quantities without obstructing the medical purposes through the decrease in kVp and the use of Dose modulation program, Care dose 4D for tube current with patient screening by weight in CT examination. Materials and Methods Each weight group(51kg~60kg, 61kg~70kg, 71kg~80kg, 81kg~90kg) consists of 5 patients from total 20 patients with follow-up abdomen CT examination. CT values and noise according to the tube ctuTent were measured, and exposure dose and image quality were compared. Somatom Sensation 16 equipment was used for measurement. Dose modulation program, Care dose 4D was used for tube current, and tube voltage was measured using 100kVp at Pre Enhancement phase on the abdomen. Examination range was compared and analyzed by applying same FOV with the recently examined tube potential of 120kVp. Results In case of 120 kVp and 100 kVp by using Dose modulation program, Care dose 4D, CT values were decreased on the whole. However, the tendency of CT values of adjacent abdominal organs were measured similarly. 1his means that the contrast resolution is not greatly influenced by the lowered tube voltage of 100 kVp. When we measured the noise of the liver, the spleen, and the descending aorta according to the weight of the patient in the image quality measurement, as the weight of the patient decreases the noise ratio was also reduced as follows : from 0.76:1 to 0.88:1 for the liver, from 0.75:1 to 0.87:1 for the descending aorta, and from 0.73:1 to 0.85:1 for the spleen. Therefore, we can conclude that high quality image can be obtained using 100 kVp in the patient having a weight of 60 kg and the height of at least 165~175 cm. If the tube voltage was reduced from 120 kVp to 100 kVp, no tube current change was observed, and the CTDIvol value was decreased over 30%. Conclusion It would be very helpful in reducing radiation exposure to perform CT examination using optimal shooting condition according to the patient’s weight and physical constitution presented by the clinical trial results. Once the standard protocol is presented at the conference or public agency, We think that the radiation exposure of a patient can be greatly decreased by using optimal shooting condition for each hospital based on the protocol.

목차

Abstract
I. 서론
II. 대상 및 방법
III. 결과
IV. 고찰
V. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

유흥준(Heung Joon Yoo),권성옥(Seong Ohk Kwon). (2008).CT 검사 시 촬영조건에 따른 Image Quality와 Dose에 관한 연구. 대한CT영상기술학회지, 10 (1), 7-14

MLA

유흥준(Heung Joon Yoo),권성옥(Seong Ohk Kwon). "CT 검사 시 촬영조건에 따른 Image Quality와 Dose에 관한 연구." 대한CT영상기술학회지, 10.1(2008): 7-14

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제