MDCT을 이용한 Cardica CT 검사에서 ECG-pulsing기능의 사용 경험 및 고찰

이용수 8

영문명
The using experiences and consideration of the ECG-pulsing method in Cardiac CT using MDCT
발행기관
대한CT영상기술학회
저자명
박현(Hyeok Park) 이현성(Hyun Seong Lee) 김태성(Tae Seong Kim) 안인현(In Hyun An) 최남길(Nam Kil Choi)
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제10권 제1호, 159~162쪽, 전체 4쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2008.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose Cardiac CT comparing with other region’s same scan range very much radiation dose. so, I wanted to know the method which can reduce radiation dose through the effective methode of ECG-pulsing method. Materials and Methods I performed the test of patients which were prescribed for Cardiac CT because of chest pain, etc. I measured patients’ heart rate before the test. When their heart rate was more than 65 times, I used the ‘B-Blocker and I analyzed the use probability and success rates of ECG-pulsing, DPL and the optimum image reconstruction data. Results Among the 200 patients, I used the ECG-pulsing in 136 cases (68%) and DPL (mSv-cm) value was from 513 to 836 (mean value : 649). Ca scoring was from 44 times to 65 times (the mean : 57 times) in HR and from 36 times to 69 times (the mean : 53 times) in CTA. I didn’t use the ECG-pulsing in 62 cases (32%). DPL (mSv-cm) value was from 922 to 1320 and mean value was 1074. Ca scoring was from 53 times to 90 times (the mean : 66 times) in HR and from 38 times to 73 times (the mean : 59 times) in CTA. I didn’t the ECG-pulsing method because when I got the Ca scoring data, mostly BPM’s maximum was more than 64 (46cases, 73%). Image reconstruction R-R interval was shown from 65% to 69%. Conclusion When I used the ECG-pulsing method, DPL dose decreased by 39.6% than I didn’t use that. With the recent development of CT equipment, I recommend much use of the ECG-pulsing method because I think that the use of ECG-pulsing method has radiation dose decreased without a drop in image quality through the supplement of diverse ECG-pulsing methods and the maximum use of ECG-pulsing in fast CT.

목차

Abstract
I. 서론
II. 대상 및 방법
III. 결과
IV. 고찰 및 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

박현(Hyeok Park),이현성(Hyun Seong Lee),김태성(Tae Seong Kim),안인현(In Hyun An),최남길(Nam Kil Choi). (2008).MDCT을 이용한 Cardica CT 검사에서 ECG-pulsing기능의 사용 경험 및 고찰. 대한CT영상기술학회지, 10 (1), 159-162

MLA

박현(Hyeok Park),이현성(Hyun Seong Lee),김태성(Tae Seong Kim),안인현(In Hyun An),최남길(Nam Kil Choi). "MDCT을 이용한 Cardica CT 검사에서 ECG-pulsing기능의 사용 경험 및 고찰." 대한CT영상기술학회지, 10.1(2008): 159-162

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제