저선량 CT Guided Interventional Study의 유용성 평가

이용수 46

영문명
The Usefulness of Low-dose Interventional CT
발행기관
대한CT영상기술학회
저자명
이일수(Il Soo Lee)
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제10권 제1호, 169~175쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2008.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose The purpose of this study was to evaluate the possibility of bone biopsy and radio frequency ablation kidney under interventional procedures using a low radiation dose. In addition, AAPM phantom test scan evaluated the image quality and the radiation dose reduction in the same condition. Materials & Methods We retrospectively reviewed cases of bone biopsy CT(lower extremity, spine) and kidney RFA CT at our hospital from January to June 2007. The procedures inducted 37 bone biopsies and 23 kidney RFA CT. In this study, CT fluoroscopy was not used. The CT equipment used GE 4 channel LightSpeed QXi scanners 1. Bone biopsy CT To assess availability of low dose at 120kVp*40~100mAs 2.5mm with intervention CT, we reviewed 37 cases of bone biopsy CT image and evaluated the success rate. 2. Kidney RFA CT It compared with previously kidney CT of 120kvp*144mAs 2.5mm and low dose of 120kVp*40mAs*2.5mm RFA CT image. For each patients, effective radiation dose calculated with a program (impact CT Monte Carlo simulation version 0.99x20/01/06). And it executed rate of success for low dose intervention CT and an image evaluation 3. AAPM phantom test Test was taken with low dose parameter (120kVp*30~100mAs*2.5mm thickness) at 10mAs interval respectively and it measured the image quality with each 4 items (CT No. noise, uniformity and low contrast resolution). Results 1. 111e success or failure of low dose bone biopsy CT evaluated to pathological result come out accurately (malignant or benign) or result is normal. 2. Bone biopsy CT is successful in 29 out of 37 patients(78.4%) with 40~80 mAs; 8 people(21.6%) finished using 100~200 mAs. 3. Kidney RFA CT was successful in 22 out of 23 patients(95.7%). When biopsy needle approached the target lesion, scan parameter used 40mAs and contrast enhanced CT using below 80mAs. When applied to a routine dose of 120kVp*144mAs, 30mm scan range 1scan, the dose calculation is CTDIVOL 19.4mGy, DLP 58.0mGy.cm, eff.dose 1.30mSv and applying 40mAs, CTDIVOL 5.4mGy, DLP 16.0mGy.cm, eff.dose 0.35 mSv. The results of AAPM phantom test is CT No. of water 0.17~0.47HU, uniformity -0.6~2.61HU and low contrast resolution was 9.5mm but noise higher as 12.20~28.95HU. Conclusion In conclusion, there are several method in reducing the radiation dose but we found out that the most common interventional CT procedure can be performed safely and successfully if using 40~80mAs. This range promotes a good radiation close reduction to patients.

목차

Abstract
I. 목적
II. 대상 및 방법
III. 결과
IV. 고찰
V. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

이일수(Il Soo Lee). (2008).저선량 CT Guided Interventional Study의 유용성 평가. 대한CT영상기술학회지, 10 (1), 169-175

MLA

이일수(Il Soo Lee). "저선량 CT Guided Interventional Study의 유용성 평가." 대한CT영상기술학회지, 10.1(2008): 169-175

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제