본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

MDCT를 이용한 Neck Angiography검사 시 조영제량 감소에 따른 화질 향상에 관한 연구

이용수 6

영문명
Evaluation of image quality as reduction of contrast volume in Neck angiography by MDCT
발행기관
대한CT영상기술학회
저자명
길미경(Mi Kyeong Kil) 정재연(Jee Yeon Chung) 김정훈(Jeong Hoon Kim)
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제10권 제1호, 21~25쪽, 전체 5쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2008.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose This study is to evaluate the effect on quality of angiographic image, when the contrast media volume is reduced in Neck angiography by MDCT. Materials and methods Tortal one hundred patients have been examined angiography by MDCT. Fifty patient(A group) of one hundred patients have been examined with 100ml contrast media, the other fifty patients (B group) have been examined with 60ml contrast media and 40ml normal saline. The speed of injection was 4-5cc per second by auto injector. Dual source CT (Definition, Siemens, Erlangen, Germany) and dual auto injector (Optivantage, TYCO) were used for this study. Patients that performed Neck angiography reconstructed 3D image and a radiologist used to 5 scales evaluated visually at the subclavian vein artifact. Results A group-50 person that 100ml contrast media by single auto injection which it uses 1point 0people (0%) and 2 points 2 people (4%) and 3 points 18 people (36%) and 4 points 21 people(42%) and 5 points with 9people(18%) seemed, B group-50 person that 60ml contrast media +Normal saline 40 ml by dual auto injection which they use 1 point 2 people(4%) and 2 points 1 people(2%), 3 points 5 people(10%) 4 points 17 people (34%) 5 points 25 people(50%) seemed. At the result, image quality improved at reduced contrast media. Conclusion The Neck angiography diagnos the carotid artery obstruction or stenosis. When examined 40% it will diminish the contrast media, it will be able to minimize the artifact due to a contrast media abundance in subclavian vein and the possibility of bringing an image quality improvement it was. The CT equipment is developed and rapidity it controls the contrast media quantity which recent existing where also the scan time is coming to be quick gradually it uses well and if it inspects, only image quality improvement it knows, until the side effect which it follows in contrast media decrease it gets and the possibility of putting out it will it thinks.

목차

Abstract
I. 서론
II. 대상 및 방법
III. 결과
IV. 고찰
V. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

길미경(Mi Kyeong Kil),정재연(Jee Yeon Chung),김정훈(Jeong Hoon Kim). (2008).MDCT를 이용한 Neck Angiography검사 시 조영제량 감소에 따른 화질 향상에 관한 연구. 대한CT영상기술학회지, 10 (1), 21-25

MLA

길미경(Mi Kyeong Kil),정재연(Jee Yeon Chung),김정훈(Jeong Hoon Kim). "MDCT를 이용한 Neck Angiography검사 시 조영제량 감소에 따른 화질 향상에 관한 연구." 대한CT영상기술학회지, 10.1(2008): 21-25

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제