영문 초록

Purpose In this study, because the time which is reached at aorta through antecubital vein after injecting contrast media is different from each person, I used Bolus Tracking method to investigate the parameters affecting the time when contrast media is reached at 100HU(T100) and studied the relationship between parameters and T100. Materials and Methods Using 64MDCT, Cadiac CT, I got the data from July and September, 2007. 100patients (male : 50, female : 50, age distribution : 21-81, average age : 57.5) were performed by injecting the contrast media at 4ml/sec through their antecubital vein except having difficulties in stopping their breath and having arrhythmia. I used Somatom Sensation Cardiac 64, Siemens and measured patients’ height and weight to know their mean Heart rate and BMI. I measured Ejection Fraction using Argus Program, Wizard Workstation. I analyzed variances of each parameter depending on T100’s variation with multiple comparison and analyzed the correlation of Heart rate, Ejection Fraction and BMI. Results According to T100’s variation caused by Heart rate, Ejection Fraction and BMI variations, the higher patients’ Heart Rate and Ejection Fraction were, the faster T100’s variations caused by Heart Rate and Ejection Fraction were. The lower their Heart Rate and Ejection Fraction were, the slower T100’s variations were, but T100’s variations caused by BMI were not affected. In the correlation between T100 and parameters, Heart Rate (p <0.01) and Ejection Fraction (p<0.05) were significant, but BMI was not significant (p>0.05). In the Heart Rate, Ejection Fraction and BMI depending on Fast (17sec and less), Medium (18 - 21 sec), Slow(22sec and over) Heart Rate was significant at Fast and Slow and Ejection Fraction was significant Fast and Slow as well as Medium and Slow (p<0.05). but BMI was not statistically significant. Conclusion Of the parameters (Heart Rate, Ejection Fraction and BMI) which would affect T100, Heart Rate was the most significant and the higher Heart Rate and Ejection Fraction were, the faster T100 was.

목차

Abstract
I. 서론
II. 대상과 방법
III. 결과
IV. 고찰 및 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

성봉옥(Bong Wook Seong),김성옥(Sung Ok Kim),김영덕(Young Deok Kim),이정호(Jong Ho Lee),최남길(Nam Gil Choi). (2008).상행대동맥의 조영증강시간에 영향을 주는 인자 관한 연구. 대한CT영상기술학회지, 10 (1), 129-133

MLA

성봉옥(Bong Wook Seong),김성옥(Sung Ok Kim),김영덕(Young Deok Kim),이정호(Jong Ho Lee),최남길(Nam Gil Choi). "상행대동맥의 조영증강시간에 영향을 주는 인자 관한 연구." 대한CT영상기술학회지, 10.1(2008): 129-133

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제