본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

MDCT를 이용한 복부 3-phase검사시 추적검사환자의 피폭선량 감소를 위한 Bolus triggering에 대한 고찰

이용수 34

영문명
Study of Bolus triggering used for reducing radiation exposure dose of follow-up patients during abdomen 3-phase examination with MDCT
발행기관
대한CT영상기술학회
저자명
민철홍(Chul Hong Min) 이성현(Sung Hyun Lee) 홍석현 강홍규(Hong Gu Kang) 정민(Myun Jang) 김기원(Ki Won Kim) 김창남(Chang Nam Kim) Jang Suk Han
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제10권 제1호, 95~98쪽, 전체 4쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2008.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose In this study, number of monitoring time is examined when Bolus triggering is applied to determine examination time according to circulation of blood for 3-phase examination to reduce exposure dose during monitoring among CTDIvol to patients. Materials and Methods The research was conducted from January 2007 to May 2007 toward 339 in-patients conducted Liver, Pancreas Protocol CT examination and patients were analyzed by disease, sex and age. 16MDCT (Somatom Sensation 16, Siemens, Germany) and Auto injector(Stellant, Medrad, U.S.A) were used for as experimental equipment and contrast medium was injected through Antecubital vein(elbow). 20G(needle) was used, monitoring location was Thoracic spine 12 by 1 second interval to examine peak time of each individual. 350mg I/ml 120cc contrast medium was injected with 3cc per second and monitoring conditions were 120 kV, 20mAs, detector collimation is 16×0.75mm. Results When analyzed by disease, sex and age, regular monitoring number was unable to find but for identical tracking examination conducted toward 35 people, 17 people had identical monitored number. Among 18 unidentical people, 17 people had ±3 times and only 1 person had 6 times different due to changed IV location and Flow rate. Conclusion Monitored number analysis was applied to experiment result and average was 9.4 times CTDIvol 39.12mGy. As minimum monitored number was 2, monitoring start time was 2 seconds after enhance to reduce CTDIvol to 8.32mGy. Also in case of follow-up patients, as error range is ±3sec, monitoring number data is recorded and managed with OCS Warning System to reduce average numbers from 9.4 times to 6 times resulting reduction of 28.96mGy that is 3 time exposure dose CTDIvol of single phase examination.

목차

Abstract
I. 서론
II. 대상 및 방법
III. 결과
IV. 고찰
V. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

민철홍(Chul Hong Min),이성현(Sung Hyun Lee),홍석현,강홍규(Hong Gu Kang),정민(Myun Jang),김기원(Ki Won Kim),김창남(Chang Nam Kim),Jang Suk Han. (2008).MDCT를 이용한 복부 3-phase검사시 추적검사환자의 피폭선량 감소를 위한 Bolus triggering에 대한 고찰. 대한CT영상기술학회지, 10 (1), 95-98

MLA

민철홍(Chul Hong Min),이성현(Sung Hyun Lee),홍석현,강홍규(Hong Gu Kang),정민(Myun Jang),김기원(Ki Won Kim),김창남(Chang Nam Kim),Jang Suk Han. "MDCT를 이용한 복부 3-phase검사시 추적검사환자의 피폭선량 감소를 위한 Bolus triggering에 대한 고찰." 대한CT영상기술학회지, 10.1(2008): 95-98

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제