CT Mammography검사 시 자세변화에 따른 영상평가 및 적정선량에 관한 연구

이용수 15

영문명
Study of image quality and optimum dose with change of position in CT Mammography
발행기관
대한CT영상기술학회
저자명
송훈(Hoon Song) 김현주(Hyeon Ju Kim) 신훈(Hoon Shin) 조인완(In Wan Cho) 오용운(Yong Woon OH) 유병헌(Byeong Heon Yoo) 김승식(Seung Sik Kim)
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제10권 제1호, 27~34쪽, 전체 8쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2008.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose The subject of this study is female breast cancer patient who had. CT mammography before and after surgery. The study covers effects on exposure dose and image quality by change of exposure condition are observed, and makes comparative, analytic study of difference between a breast image taken with supine position and the other one with prone position. Materials & Methods Qualities of supine position image were compared with those of prone position image and difference between two of the images were analyzed with change of kVp and mAs by 3grades(Equivalent, Acceptable, Unacceptable). A special equipment was used for prone position image so as to breast of the subjects don’t be squeezed. CTDIvol was recorded scanning by 120kVp/100mAs during usual scanning and 100kVp/70mAs for this study. 20 female breast cancer patients were subjects, and Somatom Sensation16(Siemens, Erlagen, Germany) was used by 2 observers in this study. Two studies were conducted on phantom. First, ion chambers were put into holes around and center of a phantom, and exposure dose on reader was recorded after scanning the phantom with change of kVp and mAs. Second, CTDIvol that was changing by exposed area differ by position of the breast phantom was measured with change of kVp and mAs, Results According to the 20 scanned images based on change of position and image quality, It gives 1 case on Equivalent, 19 cases on Acceptable and 0 case on Unacceptable. CTDIvol is measured as 7.8mGy at 120kVp/100mAs and 3.5mGy at 100kVp/70mAs. but there was no relation with position. Surface dose decreased by mean 59% and deep dose decreased by 63% at 100kVp/70mAs compared at 120kVp/100mAs in phantom study while dose is measured as 1.11mGy at 100kVp/70mAs with straighten up position for maximum exposed area which is reduced by 10% compared with a lateral position in the same condition. Conclusion It’s impossible for exposure dose to be less than a certain value in order to satisfy a proper condition, 100kVpn/70mAs, at which the image quality is not effected. In this study, it results that prone position makes fine image especially for diagnosing patients before surgery rather than supine position does. consequently, this study shows that prone position have decisive role for the accurate examination of breast cancer

목차

Abstract
I. 서론
II. 대상 및 방법
III. 결과
IV. 고찰
V. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

송훈(Hoon Song),김현주(Hyeon Ju Kim),신훈(Hoon Shin),조인완(In Wan Cho),오용운(Yong Woon OH),유병헌(Byeong Heon Yoo),김승식(Seung Sik Kim). (2008).CT Mammography검사 시 자세변화에 따른 영상평가 및 적정선량에 관한 연구. 대한CT영상기술학회지, 10 (1), 27-34

MLA

송훈(Hoon Song),김현주(Hyeon Ju Kim),신훈(Hoon Shin),조인완(In Wan Cho),오용운(Yong Woon OH),유병헌(Byeong Heon Yoo),김승식(Seung Sik Kim). "CT Mammography검사 시 자세변화에 따른 영상평가 및 적정선량에 관한 연구." 대한CT영상기술학회지, 10.1(2008): 27-34

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제