학술논문
Lymphoscintigraphy의 정량분석 시 오류 요인에 관한 평가
이용수 2
- 영문명
- Evaluation of Error Factors in Quantitative Analysis of Lymphoscintigraphy
- 발행기관
- 대한핵의학기술학회
- 저자명
- 연준호(Joon Ho Yeon) 김수영(Soo Yung Kim) 최성욱(Sung Ook Choi) 석재동(Jae Dong Seok)
- 간행물 정보
- 『핵의학기술』Vol.15 No.2, 76~82쪽, 전체 7쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2011.11.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
Purpose: Lymphoscintigraphy is absolutely being used standard examination in lymphatic diagnosis, evaluation after treatment, and it is useful for lymphedema to plan therapy. In case of lymphoscintigraphy of lower-extremity lymphedema, it had an effect on results if patients had not pose same position on the examination of 1 min, 1 hour and 2 hours after injection. So we’ll study the methods to improve confidence with minimized quantitative analysis errors by influence factors. Materials and Methods: Being used the Infinia of GE Co. we injected ⁹⁹ᵐTc-phytate 37 MBq (1.0 mCi) 4 sylinges into 40 people’s feet hypodermically from June to August 2010 in Samsung Medical Center. After we acquired images of fixed and unfixed condition, we confirmed the count values change by attenuation of soft tissue and bone according to different feet position. And we estimated 5 times increasing 2 cm of distance between ⁹⁹ᵐTc point source and detector each time to check counts difference according to distance change by different feet position. Finally, we compared 1 and 6 min lymphoscintigraphy images with same position to check the effect of quantitative analysis results owing to difference of amounts of movement of the ⁹⁹ᵐTc-phytate in the lymphatic duct. Results: Percentage difference regarding error values showed minimum 2.7% and maximum 25.8% when comparing fixed and unfixed feet position of lymphoscintigraphy examination at 1 min after injection. And count values according to distance were 173,661 (2 cm), 172,095 (4 cm), 170,996 (6 cm), 167,677 (8 cm), 169,208 counts (10 cm) which distance was increased interval of 2 cm and basal value was mean 176,587 counts, and percentage difference values were not over 2.5% such as 1.27, 1.79, 2.04, 2.42, 2.35%. Also, Assessment results about amounts of movement in lymphatic duct within 6 min until scanning after injection showed minimum 0.15%, and maximum 2.3% which were amounts of movement. We can recognize that error values represent over 20% due to only attenuation of soft tissue and bone except for distance difference (2.42%) and amounts of movement in lymphatic duct (2.3%). Conclusion: It was show that if same patients posed different feet position on the examination of 1 min, 1 hour and 2 hours after injection in the lymphoscintigraphy which is evaluating lymphatic flow of patients with lymphedema and analyzing amount of intake by lymphatic system, maximum error value represented 25.8% due to attenuation of soft tissue and bone, and PASW (Predictive Analytics Software) showed that fixed and unfixed feet position was different each other. And difference of distance between detector and feet and change of count values by difference of examination beginning time after injection influence on quantitative analysis results partially. Therefore, we'll make an effort to fix feet position and make the most of fixing board in lymphoscintigraphy with quantitative analysis.
목차
서론
대상 및 방법
결과
결론 및 고찰
요약
REFERENCES
해당간행물 수록 논문
- 의료기관 방사선 종사자의 직무별 개인피폭선량에 관한 연구
- PET/CT 검사에서 시간 입력 차이에 따른 표준화섭취계수(SUV) 변화에 대한 고찰
- ⁹⁹ᵐTc을 이용한 심근 관류 SPECT에서 Multiple Confocal SPECT System의 유용성
- Lymphoscintigraphy의 정량분석 시 오류 요인에 관한 평가
- 핵의학과 혈액검사실의 안전 관리 활동에 대한 고찰
- PET/CT 영상 획득 시 사전설정법 차이에 따른 영상 질 평가
- Brain Perfusion SPECT에서 Image Registration의 유용성
- 저선량에서의 TrueX 재구성 방법에 의한 유용성 평가
- Brain Perfusion SPECT(Diamox) 검사의 수행결과에 영향을 주는 요인
- PET/CT 장비 별 mini PACS에서 측정한 표준섭취계수(SUV)의 유용성 평가
- 기체크로마토그래프법을 이용한 [F-18]FDG의 잔류용매 분석
- 감마카메라 영상에서 분해능 향상을 위한 Xact-bone의 유용성 평가
- PET/CT 검사에서 영상의 질을 유지하기 위한 적정한 ¹⁸F-FDG 투여량의 평가
- 팬텀을 이용한 소아 PET/CT 검사 시 감쇄보정 CT 선량과 영상 평가
- QPS 프로그램에서 Myocardial extract 적용에 따른 임상적 유용성 평가
- PET/CT 검사에서 확대된 표시시야가 표준섭취계수에 미치는 영향 평가
- 방사면역측정법과 화학발광면역측정법간의 숙련도 비교평가
- 핵의학 체외검사의 진료재료비용 절감 방안
- 9-(4-[¹⁸F] Fluoro-3-hydroxymethylbutyl) guanine 합성의 자동화와 최적화에 관한 연구
- 방사선 작업 종사자의 작업화 및 작업복의 방사선 오염 분석
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- RI 등 사용 허가 대학의 정기 검사 수검 사례: 방사선학과를 대상으로
- 핵의학 갑상샘 팬텀 영상에서 보간법이 초고분해능 ResNet 모델성능에 미치는 영향에 관한 연구
- 방사성동위원소(RI) 폐기물 내 Pb-214, Bi-214 화학 분리를 통한 핵종분석 방법에 관한 연구
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!