PET/CT 검사에서 확대된 표시시야가 표준섭취계수에 미치는 영향 평가

이용수 0

영문명
The Evaluation of the Difference of the SUV Caused by DFOV Change in PET/CT
발행기관
대한핵의학기술학회
저자명
곽인석(In Suk Kwak) 이혁(Hyuk Lee) 최성욱(Sung Wook Choi) 석재동(Jae Dong Seok)
간행물 정보
『핵의학기술』Vol.15 No.2, 13~20쪽, 전체 8쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2011.11.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: The limited FOV(Field of View) of CT (Computed Tomography) can cause truncation artifact at external DFOV (Display Field of View) in PET/CT image. In our study, we measured the difference of SUV and compared the influence affecting to the image reconstructed with the extended DFOV. Materials and Methods: NEMA 1994 PET Phantom was filled with ¹⁸F(FDG) of 5.3 kBq/mL and placed at the center of FOV. Phantom images were acquired through emission scan. Shift the phantom's location to the external edge of DFOV and images were acquired with same method. All of acquired data through each experiment were reconstructed with same method, DFOV was applied 50 cm and 70 cm respectively. Then ROI was set up on the emission image, performed the comparative analysis SUV. In the clinical test, patient group shown truncation artifact was selected. ROI was set up at the liver of patient's image and performed the comparative analysis SUV according to the change of DFOV. Results: The pixel size was increase from 3.91 mm to 5.47 mm according to the DFOV increment in the centered location phantom study. When extended DFOV was applied, maxSUV of ROI was decreased from 1.49 to 1.35. In case of shifted the center of phantom location study, maxSUV was decreased from 1.30 to 1.20. The maxSUV was 1.51 at the truncated region in the extended DFOV. The difference of the maxSUV was 25.9% higher at the outside of the truncated region than inside. When the extended DFOV was applied, maxSUV was decreased from 3.38 to 3.13. Conclusion: When the extended DFOV was applied, maxSUV decreasing phenomenon can cause pixel to pixel noise by increasing of pixel size. In this reason, maxSUV was underestimated. Therefore, We should consider the underestimation of quantitative result in the whole image plane in case of patient study applied extended DFOV protocol. Consequently, the result of the quantitative analysis may show more higher than inside at the truncated region.

목차

서론
실험 재료 및 방법
결과
고찰
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

곽인석(In Suk Kwak),이혁(Hyuk Lee),최성욱(Sung Wook Choi),석재동(Jae Dong Seok). (2011).PET/CT 검사에서 확대된 표시시야가 표준섭취계수에 미치는 영향 평가. 핵의학기술, 15 (2), 13-20

MLA

곽인석(In Suk Kwak),이혁(Hyuk Lee),최성욱(Sung Wook Choi),석재동(Jae Dong Seok). "PET/CT 검사에서 확대된 표시시야가 표준섭취계수에 미치는 영향 평가." 핵의학기술, 15.2(2011): 13-20

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제