PET/CT 영상 획득 시 사전설정법 차이에 따른 영상 질 평가

이용수 0

영문명
Evaluation of the Image Quality According to the Pre-set Method in PET/CT Image
발행기관
대한핵의학기술학회
저자명
박선명(Sun Myung Park) 이혁(Hyuk Lee) 홍건철(Gun Chul Hong) 정은경(Eun Kyung Chung) 최춘기(Choon Ki Choi) 석재동(Jae Dong Seok)
간행물 정보
『핵의학기술』Vol.15 No.2, 41~46쪽, 전체 6쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2011.11.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: The result of exam using an imaging device is very closely related with the image quality. Moreover, this image quality can be changed according to the condition of image acquisition and evaluation method. In this study, we evaluated the image quality according to the difference of pre-set method in PET/CT image. Materials & Methods: PET/CT Discovery STe16 (GE Healthcare, Milwaukee, USA), Chest PET phantom (Experiment 1) and 94 NEMA phantom (Experiment 2) were used. Phantom were filled with ¹⁸F-FDG maintaining hot sphere and background ratio to 4:1. In the case of experiment 1, we set the radio activity concentration on 3.5, 6.0, 8.6 kBq/mL. In the case of experiment 2, we set the radio activity concentration on 3.3, 5.5, 7.7, 9.9, 12.1, 16.5 kBq/mL. All experiments were performed with the time-set method for 2 minutes 30 seconds per frame and the count-set method with one hundred million counts in 3D mode after CT transmission scan. For the evaluation of the image quality, we compared each results by using the NECR and SNR. Results: In the experiment 1, both the NECR and SNR were increased as radioactivity concentration getting increased. The NECR was shown as 53.7, 66.9, 91.4. and SNR was shown as 7.9, 10.0, 11.7. Both the NECR and SNR were increased in time-set method. But the count-set method's pattern was not similar with the time-set method. The NECR was shown as 53.8, 69.1, 97.8, and SNR was shown as 14.1, 14.7 14.4. The SNR was not increased in count-set method. In experiment 2, results of both the NECR and SNR were shown as 45.1, 70.6, 95.3, 115.6, 134.6, 162.2 and 7.1, 8.8, 10.6, 11.5, 12.7, 14.0. These results were shown similar patten with the experiment 1. Moreover, when the count-set method was applied, the NECR was shown as 42.1, 67.3, 92.1, 112.2, 130.7, 158.7, and SNR was shown as 15.2, 15.9, 15.6, 15.4, 15.5, 14.9. The NECR was increased but SNR was not shown same pattern. Conclusion: Increment of administered radioactivity improves the quality of image unconcerned with the pre-set method. However, NECR was not influenced by increment of total acquisition counts through simple increasing scan duration without increment of administered activity. In case of count-set method, the SNR was shown similar value despite of increment of radioactivity. So, the administered activity is more important than the scan duration. And we have to consider that evaluation of image quality using only SNR may not be appropriate.

목차

서론
실험재료 및 방법
결과
고찰 및 결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

박선명(Sun Myung Park),이혁(Hyuk Lee),홍건철(Gun Chul Hong),정은경(Eun Kyung Chung),최춘기(Choon Ki Choi),석재동(Jae Dong Seok). (2011).PET/CT 영상 획득 시 사전설정법 차이에 따른 영상 질 평가. 핵의학기술, 15 (2), 41-46

MLA

박선명(Sun Myung Park),이혁(Hyuk Lee),홍건철(Gun Chul Hong),정은경(Eun Kyung Chung),최춘기(Choon Ki Choi),석재동(Jae Dong Seok). "PET/CT 영상 획득 시 사전설정법 차이에 따른 영상 질 평가." 핵의학기술, 15.2(2011): 41-46

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제