PET/CT 검사에서 영상의 질을 유지하기 위한 적정한 ¹⁸F-FDG 투여량의 평가

이용수 0

영문명
Evaluation of Reasonable ¹⁸F-FDG Injected Dose for Maintaining the Image Quality in 3D WB PET/CT
발행기관
대한핵의학기술학회
저자명
문아름(A Reum Moon) 이혁(Hyuk Lee) 곽인석(In Suk Kwak) 최성욱(Sung Wook Choi) 석재동(Jae Dong Suk)
간행물 정보
『핵의학기술』Vol.15 No.2, 36~40쪽, 전체 5쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2011.11.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: ¹⁸F-FDG injected dose to the patient is quite different between the recommended dose from manufacturer and the actual dose applied to each of hospitals. injection of inappropriate ¹⁸F-FDG dose may not only increase the exposed dose to patients but also reduce the image quality. we thus evaluated the proper ¹⁸F-FDG injected dose to decrease the exposed dose to patients considering the image quality. Materials And Methods: NEMA Nu2-1994 phantom was filled with ¹⁸F-FDG increasing hot cylinder radioactivity concentration to 1, 3, 5, 7, 9 MBq/kg based on the ratio of 4:1 between the hot cylinder and background activity. after completing the transmission scan using ct, emission scan was acquired in 3D mode for 2 minutes 30 seconds/bed. ROI was set up on hot cylinder and background radioactivity region. after measuring SUVmax those regions, then analyzed SNR at the points. clinical experiment has been conducted the object of patients who have came to smc from november 2009 to august 2010, 97 patients without having a hepatic lesions were selected. ROI was set up in the liver and thigh area. after measuring SUVmax, the image quality was compared following the injected dose. Results: in phantom study, as the injected radioactivity concentration per unit mass was 1, 3, 5, 7, 9 MBq/kg, SUVmax was 23.1, 24.1, 24.3, 22.8, 23.6 and SNR was shown 0.48, 0.54, 0.56, 0.55, 0.55. according to increment of the injected dose, SUVmax and SNR was increased under 5 MBq/kg but they were decreased over 7 MBq/kg. in case of clinical experiment, as increased the injected radioactivity concentration per unit mass was 4.72, 5.34, 6.16, 7.41, 8.68 MBq/kg, SUVmax was 2.68, 2.67, 2.26, 1.88, 1.95 and SNR was shown 0.52, 0.53, 0.46, 0.46, 0.44. if the injected dose exceeds 5 MBq/kg, showed a decrease pattern as phantom study. Conclusion: increasing ¹⁸F-FDG injected dose considered patient’s body weight improve image quality within a certain range. if it exceeds the range, it can be reduced image quality due to random and scatter coincidences. this study indicates that the optimal injected dose was 5 MBq/kg per unit mass the injected radioactivity concentration in 3d wb pet/ct.

목차

서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

문아름(A Reum Moon),이혁(Hyuk Lee),곽인석(In Suk Kwak),최성욱(Sung Wook Choi),석재동(Jae Dong Suk). (2011).PET/CT 검사에서 영상의 질을 유지하기 위한 적정한 ¹⁸F-FDG 투여량의 평가. 핵의학기술, 15 (2), 36-40

MLA

문아름(A Reum Moon),이혁(Hyuk Lee),곽인석(In Suk Kwak),최성욱(Sung Wook Choi),석재동(Jae Dong Suk). "PET/CT 검사에서 영상의 질을 유지하기 위한 적정한 ¹⁸F-FDG 투여량의 평가." 핵의학기술, 15.2(2011): 36-40

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제