⁹⁹ᵐTc을 이용한 심근 관류 SPECT에서 Multiple Confocal SPECT System의 유용성
이용수 2
- 영문명
- Usability of Multiple Confocal SPECT SYSTEM in the Myocardial Perfusion SPECT Using ⁹⁹ᵐTc
- 발행기관
- 대한핵의학기술학회
- 저자명
- 신채호(Chae ho Shin) 표성재(Sung Jai Pyo) 김봉수(Bong Su Kim) 조용귀(Yong Gyi Cho) 조진우(Jin Woo Jo) 김창호(Chang Ho Kim)
- 간행물 정보
- 『핵의학기술』Vol.15 No.2, 65~71쪽, 전체 7쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2011.11.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
Purpose: The recently adopted multiple confocal SPECT SYSTEM (hereinafter called IQ SPECTTM) has a high difference from the conventional myocardial perfusion SPECT in the collimator form, image capture method, and image reconstruction method. This study was conducted to compare this novice equipment with the conventional one to design a protocol meeting the IQ SPECT, and also determine the characteristics and usefulness of IQ SPECT. Materials and Methods: 1. For the objects of LEHR (Low energy high resolution) collimator and Multiple confocal collimator, ⁹⁹ᵐTc 37MBq was put in the acrylic dish then each sensitivity (cpm/μCi) was measured at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. 2. Based on the sensitivity measure results, IQ SPECT Protocol was designed according to the conventional general myocardial SPECT, then respectively 278 kBq/mL, 7.4 kBq/mL, and 48 kBq/mL of ⁹⁹ᵐTc were injected into the myocardial and soft tissues and liver site by using the anthropomorphic torso phantom then the myocardial perfusion SPECT was run. 3. For the comparison of FWHMs (Full Width at Half Maximum) resulted from the image reconstruction of LEHR collimator, the FWHMs (mm) were measured with only algorithms changed, in the case of the FBP (Filtered Back projection) method- a reconstruction method of conventional myocardial perfusion SPECT, and the 3D OSEM (Ordered subsets expectation maximization) method of IQ SPECT, by using ⁹⁹ᵐTc Line source. Results: 1. The values of IQ SPECT collimator sensitivity (cpm/μCi) were 302, 382, 655, 816, 1178, and those of LEHR collimator were measured as 204, 204, 202, 201, 198, both at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. It was found the difference of sensitivity increases up to 4 times at the distance of 30 cm in the cases of IQ SPECT and LEHR. 2. The myocardial perfusion SPECT Protocol was designed according to the geometric characteristics of IQ SPECT based on the sensitivity results, then the phantom test for the aforesaid protocol was conducted. As a result, it was found the examination time can be reduced 1/4 compared to the past. 3. In the comparison of FWHMs according to the reconstructed algorithm in the FBP method and 3D OSEM method followed after the SEPCT test using a LEHR collimator, the result was obtained that FWHM rose around twice in the 3D OSEM method. Conclusion : The IQ SPECT uses the Multiple confocal collimator for the myocardial perfusion SPECT to enhance the sensitivity and also reduces examination time and contributes to improvement of visual screen quality through the myocardial-specific geometric image capture method and image reconstruction method. Due to such benefits, it is expected patients will receive more comfortable and more accurate examinations and it is considered a further study is required using additional clinical materials.
목차
서론
실험재료 및 방법
결과
결론
요약
REPERENCES
해당간행물 수록 논문
- 의료기관 방사선 종사자의 직무별 개인피폭선량에 관한 연구
- PET/CT 검사에서 시간 입력 차이에 따른 표준화섭취계수(SUV) 변화에 대한 고찰
- ⁹⁹ᵐTc을 이용한 심근 관류 SPECT에서 Multiple Confocal SPECT System의 유용성
- Lymphoscintigraphy의 정량분석 시 오류 요인에 관한 평가
- 핵의학과 혈액검사실의 안전 관리 활동에 대한 고찰
- PET/CT 영상 획득 시 사전설정법 차이에 따른 영상 질 평가
- Brain Perfusion SPECT에서 Image Registration의 유용성
- 저선량에서의 TrueX 재구성 방법에 의한 유용성 평가
- Brain Perfusion SPECT(Diamox) 검사의 수행결과에 영향을 주는 요인
- PET/CT 장비 별 mini PACS에서 측정한 표준섭취계수(SUV)의 유용성 평가
- 기체크로마토그래프법을 이용한 [F-18]FDG의 잔류용매 분석
- 감마카메라 영상에서 분해능 향상을 위한 Xact-bone의 유용성 평가
- PET/CT 검사에서 영상의 질을 유지하기 위한 적정한 ¹⁸F-FDG 투여량의 평가
- 팬텀을 이용한 소아 PET/CT 검사 시 감쇄보정 CT 선량과 영상 평가
- QPS 프로그램에서 Myocardial extract 적용에 따른 임상적 유용성 평가
- PET/CT 검사에서 확대된 표시시야가 표준섭취계수에 미치는 영향 평가
- 방사면역측정법과 화학발광면역측정법간의 숙련도 비교평가
- 핵의학 체외검사의 진료재료비용 절감 방안
- 9-(4-[¹⁸F] Fluoro-3-hydroxymethylbutyl) guanine 합성의 자동화와 최적화에 관한 연구
- 방사선 작업 종사자의 작업화 및 작업복의 방사선 오염 분석
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- RI 등 사용 허가 대학의 정기 검사 수검 사례: 방사선학과를 대상으로
- 핵의학 갑상샘 팬텀 영상에서 보간법이 초고분해능 ResNet 모델성능에 미치는 영향에 관한 연구
- 방사성동위원소(RI) 폐기물 내 Pb-214, Bi-214 화학 분리를 통한 핵종분석 방법에 관한 연구
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!