FDG 사용 시 Dose Calibrator에 따른 SUV에 미치는 영향

이용수 0

영문명
The Effect of Using Two Different Type of Dose Calibrators on In Vivo Standard Uptake Value of FDG PET
발행기관
대한핵의학기술학회
저자명
박영재(Young Jae Park) 방성애(Seong Ae Bang) 이승민(Seung Min Lee) 김상언(Sang Un Kim) 고길만(Gil Man Ko) 이경재(Kyung Jae Lee) 이인원(In Won Lee)
간행물 정보
『핵의학기술』Vol.14 No.1, 115~121쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2010.06.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: The purpose of this study is to measure F-18 FDG with two different types of dose calibrator measuring radionuclide and radioactivity and investigate the effect of F-18 FDG on SUV (Standard Uptake Value) in human body. Materials and Methods: Two different dose calibrators used in this study are CRC-15 Dual PET (Capintec) and CRC-15R (Capintec). Inject 1 mL, 2 mL, 3 mL of F-18 FDG into three 2 mL syringes, respectively, and measure initial radioactivity from each dose calibrator. Then measure and record radioactivity at 30 minute interval for 270 minutes. According to the initial radioactivity, linearity between decay factor driven from radioactive decay formula and the values measured by dose calibrator have been analyzed by simple linear regression. Fine linear regression line optimizing values measured with CRC-15 through regression analysis on the basis of the volume of which the measured value is close to the most ideal one in CRC-15 Dual PET. Create ROI on lung, liver, and region part of 50 persons who has taken PET/CT test, applying values from linear regression equation, and find SUV. We have also performed paired t-test to examine statistically significant difference in the radioactivity measured with CRC-15 Dual PET, CRC-15R and its SUV. Results: Regression analysis of radioactivity measured with CRC-15 Dual PET and CRC-15R shows results as follows: in the case 1 mL, the r statistic representing correlation was 0.9999 and linear regression equation was y=1.0345x+0.2601; in 2 mL case, r=0.9999, linear regression equation y=1.0226x+0.1669; in 3 mL case, r=0.9999, linear regression equation y=1.0094x+0.1577. Based on the linear regression equation from each volume, t-test results show significant difference in SUV of ROI in lung, liver, region part in all three case. P-values in each case are as follows: in 1 mL case, lung, liver and region (p<0.0001); in 2 mL case, lung (p<0.002), liver and region (p<0.0001); in 3 mL case, lung (p<0.044), liver and region (p<0.0001). Conclusion: Radioactivity measured with CRC-15 Dual PET, CRC-15R, dose calibrator for F-18 FDG test, do not show difference correlation, while these values infer that SUV has significant differences in the aspect of uptake in human body. Therefore, it is necessary to consider the difference of SUV in human body when using these dose calibrator.

목차

서론
실험재료 및 방법
결과
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

박영재(Young Jae Park),방성애(Seong Ae Bang),이승민(Seung Min Lee),김상언(Sang Un Kim),고길만(Gil Man Ko),이경재(Kyung Jae Lee),이인원(In Won Lee). (2010).FDG 사용 시 Dose Calibrator에 따른 SUV에 미치는 영향. 핵의학기술, 14 (1), 115-121

MLA

박영재(Young Jae Park),방성애(Seong Ae Bang),이승민(Seung Min Lee),김상언(Sang Un Kim),고길만(Gil Man Ko),이경재(Kyung Jae Lee),이인원(In Won Lee). "FDG 사용 시 Dose Calibrator에 따른 SUV에 미치는 영향." 핵의학기술, 14.1(2010): 115-121

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제