본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

FDG 합성 후 질소가스를 이용한 튜빙의 잔류 ¹⁸F-FDG 최소화를 위한 방법의 유용성

이용수 0

영문명
A Study on Minimizing the Residual ¹⁸F-FDG in the Tubing Using Nitrogen Gas
발행기관
대한핵의학기술학회
저자명
김동일(Dong Il Kim) 박훈(Hoon Park) 석재동(Jae Dong Seok)
간행물 정보
『핵의학기술』Vol.14 No.1, 8~12쪽, 전체 5쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2010.06.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: In ¹⁸F-FDG automated synthesizer, deliver is done in automated mode after synthesis until the dispenser. After the delivery, the yield is calculated from the radioactivity which was read by the dose calibrator located in the dispenser. However, when the distance between the automated synthesizer and the dispenser is far, there are ¹⁸F-FDG residues, which results in loss of the amount of ¹⁸F-FDG. This study investigated the usefulness of a method that minimizes ¹⁸F-FDG residues. Materials and Methods: The structure of the tubing between the (TRACERlab Mx FDG; GE.) and the dispenser is that the distance is 8 m and the internal diameter is 1/16 inch. The synthesis process of The module goes through the synthesis process of trap, synthesis, delivery in the automated module. The time taken for synthesis is about 25 to 26 minutes, after which rinsing is done. However, after rinsing, as the distance of the tubing increased, there were 10~13% of ¹⁸F-FDG residues. Therefore, a method of using push syringe and N2 gas in manual mode to minimize ¹⁸F-FDG residues is analyzed. Results: In manual mode, there were ¹⁸F-FDG residues of 4~5% for the push syringe, and there were ¹⁸F-FDG residues of less than 1% for the N2 gas, which showed that the method using N2 gas had superior usefulness. Also, there were no ¹⁸F-FDG residues in the cleaning the next day. Conclusion: The distance between the synthesizer and the dispenser needs to be reduced as much as possible, to reduce the rate of loss of ¹⁸F-FDG resulting from the distance of the tubing. However, in case the distance between the synthesizer and the dispenser has to be increased due to the system structure, using push syringe and N2 gas simultaneously is a useful method for minimizing ¹⁸F-FDG residues.

목차

Introduction
Materials and Methods
Results
Conclusion
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김동일(Dong Il Kim),박훈(Hoon Park),석재동(Jae Dong Seok). (2010).FDG 합성 후 질소가스를 이용한 튜빙의 잔류 ¹⁸F-FDG 최소화를 위한 방법의 유용성. 핵의학기술, 14 (1), 8-12

MLA

김동일(Dong Il Kim),박훈(Hoon Park),석재동(Jae Dong Seok). "FDG 합성 후 질소가스를 이용한 튜빙의 잔류 ¹⁸F-FDG 최소화를 위한 방법의 유용성." 핵의학기술, 14.1(2010): 8-12

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제