이중 에너지 엑스레이 흡수기의 가동 시간에 따른 골밀도 값의 평가

이용수 0

영문명
The Bone Mineral Density Value According to the Operating Time of the Dual Energy X-ray
발행기관
대한핵의학기술학회
저자명
이해정(Hae Jung Lee) 김호성(Ho Sung Kim) 김은혜(Eun Hye Kim)
간행물 정보
『핵의학기술』Vol.14 No.1, 40~45쪽, 전체 6쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2010.06.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: Recently, the performance of the X-ray tube was very much improved by the power generation of the technology. However, the overload of equipment is occurred by the increment of the equipment operating time according to the increment of the examination number of cases. The X-ray dose can change by heat occurrence of the X-ray tube due to this. Moreover, the change of the bone mineral density value is possible to occur. Therefore, We tries to whether the change of the bone mineral density value of each equipment according to the difference of the examination number of cases and operating time occur or not. Materials and Methods: The BMD value was measured by the Aluminum Spine Phantom and the European Spine Phantom in each equipment, in order to find out about the difference of the time general classification bone mineral density value by using the Dual energy X-ray absorptiometry. And after scanning each phantom by using X-ray dose meter (Unfors Mult-O-Meter), a dose was measured by the same condition. As to, an average and standard deviation were found and the change of each equipment much BMD value was compared and it evaluated. Results: Mean±SD of each equipment by using the Aluminum Spine Phantom, A equipment was 1.174±0.002, 1.171±0.005, 1.173±0.005, B equipment was 1.186±0.003, 1.187±0.003, 1.185±0.003, C equipment was 1.180±0.003, 1.182±0.004, 1.183±0.002, D equipment was 1.188± 0.004, 1.185±0.003, 1.185±0.004. By using the European Spine Phantom, A equipment was 1.143±0.006, 1.153± 0.009, 1.161±0.003, B equipment was 1.134±0.004, 1.13±0.008, 1.127±0.015, C equipment was 1.143±0.006, 1.134±0.01, 1.133±0.006, D equipment was 1.14±0.001, 1.122±0.002, 1.131±0.008, altogether included in the normal range. Conclusion: There was no significant change of the BMD value of using a phantom by time zones. Therefore, if the quality control is made to use the extent management method of the equipment for beginning in the present application, the reliability of the BMD equipment will be able to be enhanced.

목차

서론
실험재료 및 방법
결과
고찰
결론
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

이해정(Hae Jung Lee),김호성(Ho Sung Kim),김은혜(Eun Hye Kim). (2010).이중 에너지 엑스레이 흡수기의 가동 시간에 따른 골밀도 값의 평가. 핵의학기술, 14 (1), 40-45

MLA

이해정(Hae Jung Lee),김호성(Ho Sung Kim),김은혜(Eun Hye Kim). "이중 에너지 엑스레이 흡수기의 가동 시간에 따른 골밀도 값의 평가." 핵의학기술, 14.1(2010): 40-45

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제