본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

²⁰¹Tl을 이용한 레이노 검사에서 동적 Composite 영상의 유용성

이용수 0

영문명
Usefulness of Flow Composite Image in Raynaud Scan (²⁰¹Tl)
발행기관
대한핵의학기술학회
저자명
김대연(Dae Yeon Kim) 신규설(Gyoo Seol Shin) 오은정(Eun Jung Oh) 김건재(Gun Jae Kim)
간행물 정보
『핵의학기술』Vol.14 No.1, 101~104쪽, 전체 4쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2010.06.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: Raynaud scan is divided to flow, blood pool and local-delay image. Usually, we evaluate comparison through blood pool and local-delay image. We will evaluate about usability when comparative observe blood image and local-delay image in Raynaud scan that used ²⁰¹Tl as making flow image to one sheet of images. Materials and Methods: We have selected 29 Raynaud phenomenon patients aged 14~68 years who visited department of vascular surgery between Feb. 2008 and Aug. 2009. An intravenous injection ²⁰¹Tl of 111 MBq (3 mCi) to opposite side diagonal line limbs above an internal auditing department. Equipment used Philips gamma camera forte A-Z, and collimator used LEHR. Matrix size set up to each 64×64, 128×128, 256×256 and zoom factor used to full field. Protocol of dynamic is 2 second to 155 frames. Blood pool and delay count to 300 second. We set up ROI by a foundation to data acquired in PEGASYS processing program. Each results were analyzed with the SPSS 12.0 statistical software. Results: Each averages of count ratio (Rt / Lt) to have been given at composite image, a blood pool image, delay images analyzed at Raynaud phenomenon patients is 1.25±0.39, 1.20±0.33, 1.11±0.17. The sample analysis results of blood pool image and delay image contented itself with p<0.029. Also, there don’t have been each difference, and blood pool image, delay image regarding composite image was able to know. Conclusion: We were able to give help for comparison to evaluate a blood pool image and a local delay image at the Raynaud scan which used ²⁰¹Tl while making a flow image to one sheet image. Identification to be visual too was possible. If you are proceeded a researcher that there was further depth, you are more appropriate for, and you may get useful information.

목차

서론
실험재료 및 방법
결 과
고찰 및 결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김대연(Dae Yeon Kim),신규설(Gyoo Seol Shin),오은정(Eun Jung Oh),김건재(Gun Jae Kim). (2010).²⁰¹Tl을 이용한 레이노 검사에서 동적 Composite 영상의 유용성. 핵의학기술, 14 (1), 101-104

MLA

김대연(Dae Yeon Kim),신규설(Gyoo Seol Shin),오은정(Eun Jung Oh),김건재(Gun Jae Kim). "²⁰¹Tl을 이용한 레이노 검사에서 동적 Composite 영상의 유용성." 핵의학기술, 14.1(2010): 101-104

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제