동적 영상 획득 방식을 이용한 정적 영상의 움직임 보정
이용수 2
- 영문명
- The Application of Dynamic Acquisition with Motion Correction for Static Image
- 발행기관
- 대한핵의학기술학회
- 저자명
- 윤석환(Seok Hwan Yoon) 승종민(Jong Min Seung) 김계환(Kye Hwan Kim) 김재일(Jae Il Kim) 이형진(Hyung Jin Lee) 김진의(Jin Eui Kim) 김현주(Hyun Joo Kim)
- 간행물 정보
- 『핵의학기술』Vol.14 No.1, 46~53쪽, 전체 8쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2010.06.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
Purpose: The static image of nuclear medicine study should be acquired without a motion, however, it is difficult to acquire static image without movement for the serious patients, advanced aged patients. These movements cause decreases in reliability for quantitative and qualitative analysis, therefore re-examination was inevitable in the some cases. Consequently, in order to improve the problem of motion artifacts, the authors substituted the dynamic acquisition technique for the static acquisition, using motion correction. Materials and Methods: A capillary tube and IEC body phantom were used. First, the static image was acquired for 60 seconds while the dynamic images were acquired with a protocol, 2 sec/frame×30 frames, under the same parameter and the frames were summed up into one image afterwards. Also, minimal motion and excessive motion were applied during the another dynamic acquisition and the coordinate correction was applied towards X and Y axis on the frames where the motion artifact occurred. But the severe blurred images were deleted. Finally, the resolution and counts were compared between the static image and the summed dynamic images which before and after applying motion correction, and the signal of frequency was analysed after frequency spatial domain was transformed into 2D FFT. Supplementary examination, the blind test was performed by the nuclear medicine department staff. Results: First, the resolution in the static image and summed dynamic image without motion were 8.32 mm, 8.37 mm on X-axis and 8.30 mm, 8.42 mm on Y-axis, respectively. The counts were 484 kcounts, 485 kcounts each, so there was nearly no difference. Secondly, the resolution in the image with minimal motion applying motion correction was 8.66 mm on X-axis, 8.85 mm on Y-axis and had 469 kcounts while the image without motion correction was 21.81 mm, 24.02 mm and 469 kcounts in order. So, this shows the image with minimal motion applying motion correction has similar resolution with the static image. Lastly, the resolution in the images with excessive motion applying motion correction were 9.09 mm on X-axis, 8.83 mm on Y-axis and had 469 kcounts while the image without motion correction was 47.35 mm, 40.46 mm and 255 kcounts in order. Although there was difference in counts because of deletion of blurred frames, we could get similar resolution. And when the image was transformed into frequency, the high frequency was decreased by the movement. However, the frequency was improved again after motion correction. In the blind test, there was no difference between the image applying motion correction and the static image without motion. Conclusion: There was no significant difference between the static image and the summed dynamic image. This technique can be applied to patients who may have difficulty remaining still during the imaging process, so that the quality of image can be improved as well as the reliance for analysis of quantity. Moreover, the re-examination rate will be considerably decreased. However, there is a limit of motion correction, more time will be required to successfully image the patients applying motion correction. Also, the decrease of total counts due to deletion of the severe blurred images should be calculated and the proper number of frames should be acquired.
목차
서론
실험재료 및 방법
결과
결론 및 고찰
요약
REFERENCES
해당간행물 수록 논문
- PET/CT 검사에서 호흡에 따른 인공산물을 줄이기 위한 Average CT의 유용성
- 동적 영상 획득 방식을 이용한 정적 영상의 움직임 보정
- 핵의학과 Video Display Terminals Syndrome 유해요인 조사 및 개선에 관한 연구
- ⁹⁹ᵐTc-DTPA를 이용한 사구체 여과율 측정에서 주사 전 선량계수치의 평가
- F-18-FPCIP 뇌 영상에서 True-X 재구성 기법을 기반으로 했을 때의 Iteration과 Subset의 영향
- 한국인 일반인의 혈청 25-Hydroxy Vitamin D₃의 분석
- 이중 에너지 엑스레이 흡수기의 가동 시간에 따른 골밀도 값의 평가
- ²⁰¹Tl을 이용한 레이노 검사에서 동적 Composite 영상의 유용성
- PET/CT 2D와 3D 영상 획득에서 방사능 집적에 따른 방사능 농도의 평가
- 산란보정 전, 후의 SPECT 대조도 및 분해능 평가
- 폐와 심근에서 전이성 석회화가 발견된 골 스캔
- Fusion & Maximum Intensity Projection 3D 재구성 영상에서 Region Cut Subtraction의 유용성
- 반사성교감신경 이영양증후군 환자의 삼상 골 스캔 시 Half Body 혈액 풀 영상의 적용
- FDG 사용 시 Dose Calibrator에 따른 SUV에 미치는 영향
- 통계적 분석을 통한 Insulin의 정상 참고치 설정
- FDG 합성 후 질소가스를 이용한 튜빙의 잔류 ¹⁸F-FDG 최소화를 위한 방법의 유용성
- PET/CT 3차원 영상 획득에서 부분용적효과 감소를 위한 재구성법의 최적화
- Breast Specific Gamma Imaging 장비의 성능평가
- Phytate를 이용한 감시림프절 검사 시 Filter의 유용성 평가
- 전신 뼈 스캔 후 경과 시간 차이에 따른 ²⁰¹Tl 심근관류 SPECT 영상의 영향 평가
- 정적 영상에서 Noise Reduction Software의 이해와 적용
- 감마영상과 실사영상의 Fusion
- 전신 뼈 검사에서 Wide Beam Reconstruction 기법의 유용성
- 서울아산병원의 적혈구 표지 방법에서 교반 시간 차이에 따른 표지 효율의 분석
- 저칼슘혈증 예측지표로서 부갑상선 호르몬 검사반응시간에 따른 유용성
- 고용량 방사성옥소 치료 병실의 최대치 산출
- ⁹⁹ᵐTc-DMSA 신장 검사에서 ROI 설정 방법에 따른 정량분석 차이에 관한 연구
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 방사선학과 학생 실습환경에 관한 연구: 실습실 내 미세먼지, 휘발성유기화합물 위해도를 중심으로
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- 추출 크로마토그래피를 이용한 55Fe와 59/63Ni의 화학분리 중 목적원소 및 방해원소 거동 특성 연구
- 진단참고 준위를 적용한 선량 변화에 따른 영상 품질의 변화 평가
- 호주 방사선 의료 전문가 면허제도 및 교육과정 고찰: 진단방사선사를 중심으로
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!