본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Fusion & Maximum Intensity Projection 3D 재구성 영상에서 Region Cut Subtraction의 유용성

이용수 0

영문명
Usefulness of Region Cut Subtraction in Fusion & MIP 3D Reconstruction Image
발행기관
대한핵의학기술학회
저자명
문아름(A Reum Moon) 지용기(Yong Gi Chi) 최성욱(Sung Wook Choi) 이혁(Hyuk Lee) 이규복(Kyoo Bok Lee) 석재동(Jae Dong Seok)
간행물 정보
『핵의학기술』Vol.14 No.1, 18~23쪽, 전체 6쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2010.06.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: PET/CT combines functional and morphologic data and increases diagnostic accuracy in a variety of malignancies. Especially reconstructed Fusion PET/CT images or MIP (Maximum Intensity Projection) images from a 2-dimensional image to a 3-dimensional one are useful in visualization of the lesion. But in Fusion & MIP 3D reconstruction image, due to hot uptake by urine or urostomy bag, lesion is overlapped so it is difficult that we can distinguish the lesion with the naked eye. This research tries to improve a distinction by removing parts of hot uptake. Materials and Methods: This research has been conducted the object of patients who have went to our hospital from September 2008 to March 2009 and have a lot of urine of remaining volume as disease of uterus, bladder, rectum in the result of PET/CT examination. We used GE Company’s Advantage Workstation AW4.3 05 Version Volume Viewer program. As an analysis method, set up ROI in region of removal in axial volume image, select Cut Outside and apply same method in coronal volume image. Next, adjust minimum value in Threshold of 3D Tools, select subtraction in Advanced Processing. It makes Fusion & MIP images and compares them with the image no using Region Cut Definition. Results: In Fusion & MIP 3D reconstruction image, it makes Fusion & MIP images and compares them by using Advantage Workstation AW4.3 05’s Region Cut Subtraction, parts of hot uptake according to patient’s urine can be removed. Distinction of lesion was clearly reconstructed in image using Region Cut Definition. Conclusion: After examining the patients showing hot uptake on account of volume of urine intake in bladder, in process of reconstruction image, if parts of hot uptake would be removed, it could contribute to offering much better diagnostic information than image subtraction of conventional method. Especially in case of disease of uterus, bladder and rectum, it will be helpful for qualitative improvement of image.

목차

서론
실험재료 및 방법
결과
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

문아름(A Reum Moon),지용기(Yong Gi Chi),최성욱(Sung Wook Choi),이혁(Hyuk Lee),이규복(Kyoo Bok Lee),석재동(Jae Dong Seok). (2010).Fusion & Maximum Intensity Projection 3D 재구성 영상에서 Region Cut Subtraction의 유용성. 핵의학기술, 14 (1), 18-23

MLA

문아름(A Reum Moon),지용기(Yong Gi Chi),최성욱(Sung Wook Choi),이혁(Hyuk Lee),이규복(Kyoo Bok Lee),석재동(Jae Dong Seok). "Fusion & Maximum Intensity Projection 3D 재구성 영상에서 Region Cut Subtraction의 유용성." 핵의학기술, 14.1(2010): 18-23

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제