본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

핵의학 검체검사 정도관리의 개선을 위한 Westgard Multi-Rules의 적용

이용수 0

영문명
Application of Westgard Multi-Rules for Improving Nuclear Medicine Blood Test Quality Control
발행기관
대한핵의학기술학회
저자명
정흥수(Heung Soo Jung) 배진수(Jin Soo Bae) 신용환(Yong Hwan Shin) 김지영(Ji Young Kim) 석재동(Jae Dong Seok)
간행물 정보
『핵의학기술』Vol.16 No.1, 115~118쪽, 전체 4쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2012.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: The Levey-Jennings chart controlled measurement values that deviated from the tolerance value (mean ± 2SD or ± 3SD). On the other hand, the upgraded Westgard Multi-Rules are actively recommended as a more efficient, specialized form of hospital certification in relation to Internal Quality Control. To apply Westgard Multi-Rules in quality control, credible quality control substance and target value are required. However, as physical examinations commonly use quality control substances provided within the test kit, there are many difficulties presented in the calculation of target value in relation to frequent changes in concentration value and insufficient credibility of quality control substance. This study attempts to improve the professionalism and credibility of quality control by applying Westgard Multi-Rules and calculating credible target value by using a commercialized quality control substance. Materials and Methods : This study used Immunoassay Plus Control Level 1, 2, 3 of Company B as the quality control substance of Total T3, which is the thyroid test implemented at the relevant hospital. Target value was established as the mean value of 295 cases collected for 1 month, excluding values that deviated from ± 2SD. The hospital quality control calculation program was used to enter target value. 12s, 22s, 13s, 2 of 32s, R4s, 41s, 10x‾, 7T of Westgard Multi-Rules were applied in the Total T3 experiment, which was conducted 194 times for 20 days in August. Based on the applied rules, this study classified data into random error and systemic error for analysis. Results: Quality control substances 1, 2, and 3 were each established as 84.2 ng/㎗, 156.7 ng/㎗, 242.4 ng/㎗ for target values of Total T3, with the standard deviation established as 11.22 ng/㎗, 14.52 ng/㎗, 14.52 ng/㎗ respectively. According to error type analysis achieved after applying Westgard Multi-Rules based on established target values, the following results were obtained for Random error, 12s was analyzed 48 times, 13s was analyzed 13 times, R4s was analyzed 6 times, for Systemic error, 22s was analyzed 10 times, 41s was analyzed 11 times, 2 of 32s was analyzed 17 times, 10x‾ was analyzed 10 times, and 7T was not applied. For uncontrollable Random error types, the entire experimental process was rechecked and greater emphasis was placed on re-testing. For controllable Systemic error types, this study searched the cause of error, recorded the relevant cause in the action form and reported the information to the Internal Quality Control committee if necessary. Conclusions : This study applied Westgard Multi-Rules by using commercialized substance as quality control substance and establishing target values. In result, precise analysis of Random error and Systemic error was achieved through the analysis of 12s, 22s, 13s, 2 of 32s, R4s, 41s, 10x‾, 7T rules. Furthermore, ideal quality control was achieved through analysis conducted on all data presented within the range of ± 3SD. In this regard, it can be said that the quality control method formed based on the systematic application of Westgard Multi-Rules is more effective than the Levey-Jennings chart and can maximize error detection.

목차

서론
실험대상 및 방법
결과
고찰 및 결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

정흥수(Heung Soo Jung),배진수(Jin Soo Bae),신용환(Yong Hwan Shin),김지영(Ji Young Kim),석재동(Jae Dong Seok). (2012).핵의학 검체검사 정도관리의 개선을 위한 Westgard Multi-Rules의 적용. 핵의학기술, 16 (1), 115-118

MLA

정흥수(Heung Soo Jung),배진수(Jin Soo Bae),신용환(Yong Hwan Shin),김지영(Ji Young Kim),석재동(Jae Dong Seok). "핵의학 검체검사 정도관리의 개선을 위한 Westgard Multi-Rules의 적용." 핵의학기술, 16.1(2012): 115-118

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제