학술논문
수신증을 진단 받은 소아 환자의 DMSA 신장 검사에서 정확한 관심영역 설정에 대한 고찰
이용수 2
- 영문명
- The Consideration of the Region of Interest on ⁹⁹ᵐTc-DMSA Renal Scan in Pediatric Hydronephrosis Patients
- 발행기관
- 대한핵의학기술학회
- 저자명
- 남궁혁(Hyuk Namkoong) 이동혁(Dong Hyuk Lee) 오신현(Shin Hyun Oh) 조석원(Seok Won Cho) 박훈희(Hoon Hee Park) 김정열(Jung Yul Kim) 김재삼(Jae Sam Kim) 이창호(Chang Ho Lee)
- 간행물 정보
- 『핵의학기술』Vol.16 No.1, 27~33쪽, 전체 7쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2012.04.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
Purpose: Most of diagnosis in the pediatric hydronephrosis patients have been performed ⁹⁹ᵐTc-DMSA renal scan. Then the region of interest (ROI) is set for comparative analysis of uptake ratio in left-right kidney after acquiring the image. But if the equipment set an automatic ROI, the ROI could include expanded renal pelvis due to hydronephrosis and the uptake ratio of left-right kidney will be incorrect result. Therefore this study compared both ROIs including expanded renal pelvis and excluding renal pelvis through experiment using normal kidney phantom and expanded renal pelvis phantom and suggested setting method of improved ROI. In addition, this study have been helped by readout doctor for investigate distinction radiopharmaceutical uptake between renal cortex and remained urine by expanded renal pelvis. Materials and Methods: The both of renal phantoms were filled with water and shacked with ⁹⁹ᵐTcO4 111 MBq. In order to describe the expanded renal pelvis, the five latex balloon were all filled with 10 mL water and each of balloon was mixed with ⁹⁹ᵐTcO4 18.5, 37, 55.5, 74, 92.5 MBq. And we made phantom with fixed ⁹⁹ᵐTcO4 activity of 37 MBq and mixed water 5, 10, 15, 20, 25 mL in each balloon. The left kidney was fixed its shape and the right kidney was modified like as hydronephrosis kidney by attached the latex balloons. And the acquiring counts were 2 million. After acquisition, we compared the image of ROI with Expanded renal pelvis and the image of ROI without renal pelvis for analyzing difference in the uptake ratio of left-right kidney and for reproducibility, set the ROI 5 times in the same images. Patients were injected ⁹⁹ᵐTc-DMSA 1.5~1.9 MBq/㎏ and scanned 3 to 4 hours after injection. The each of 3 skillful radio technologists performed the comparing estimation by setting ROI. To determine statistical significance between two data, SPSS (ver. 17) Wilcoxon Signed Ranks Test was used. Results: As a result of renal phantom’s experiment, we compared with average of counts Background (BKG) ratios in the setting of ROI including expanded renal pelvis and setting of excluding expanded renal pelvis. Therefore, they can obtain changed counts and changed ratios. Patient also can obtain same results. In addition, the radiopharmaceutical uptake in expanded renal pelvis was come out the remained urine that couldn’t descend to ureter by the help of readout doctor. Conclusion: As above results, the case of setting ROI including expanded renal pelvis was more abnormally increasing uptake ratio than the case of setting ROI excluding expanded renal pelvis in analysis the uptake ratio in left-right kidney of hydronephrosis. Because of the work convenience and prompted analysis, the automatic ROI is generally used. But in case of the hydronephrosis study, we should set the manual ROI without expanded renal pelvis for an accurate observation of the uptake ratio of left-right kidney since the radiopharmaceutical uptake in expanded renal pelvis is the remained urine.
목차
서론
대상 및 방법
결과
결론
요약
REFERENCES
해당간행물 수록 논문
- 수신증을 진단 받은 소아 환자의 DMSA 신장 검사에서 정확한 관심영역 설정에 대한 고찰
- 단 반감기 핵종을 이용한 PET 검사 시 영상 획득 시간에 따른 정량성 평가
- 핵의학 검체검사 정도관리의 개선을 위한 Westgard Multi-Rules의 적용
- Tl-201을 이용한 심근관류 SPECT에서 Body contour와 Circular mode의 영상 획득 차이에 따른 영상의 질 비교
- 자동합성장치에 따른 ¹⁸F-FDG의 방사선분해 평가
- ⁹⁹ᵐTc-HMPAO 뇌혈류 SPECT 검사 시 환자에 따른 뇌조직 추출률에 대한 고찰
- 핵의학과 전용화장실에서 측정된 표면오염도 및 공간선량율에 대한 연구
- 전신 PET/CT 검사에서 환자의 팔 위치에 따른 CT 유효선량의 비교 연구
- 치밀형 유방에서 유방특이감마영상검사의 유용성 평가
- List Mode에서 PET/CT Scanner의 직선성 평가
- 방사성의약품 투여 시 피폭선량 저감에 대한 연구
- Myocardial SPECT시 COR에서 위치변화에 따른 Image Uniformity 비교
- 게이트심장혈액풀 스캔에서 환자의 자세 변화에 따른 심박출계수의 변화 연구
- 게이트 심장 혈액풀 스캔에서 좌전사위상 각도의 변화에 따른 정량적 지표 비교
- PET/CT 검사에서 SharpIR 재구성 방법의 평가
- Article TOF 기법을 이용한 PET/CT 검사에서 적정 스캔 시간에 대한 정량적 평가
- 핵의학과 환경미화원의 일시 출입자 분류에 대한 고찰
- ⁹⁹ᵐTc 표지화합물을 사용한 심근 관류 SPECT 검사에서 심장과 타 장기와의 중첩 방지를 위한 자세 변화의 유용성
- 동적 신장 신티그래피 검사 시 사용되는 Gates 법과 Modified Gates 법의 사구체 여과율 비교에 관한 고찰
- BIO-RAD 정도관리 물질을 이용한 방사면역측정법의 Acceptable Range 설정에 대한 제언
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 방사선학과 학생 실습환경에 관한 연구: 실습실 내 미세먼지, 휘발성유기화합물 위해도를 중심으로
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- 추출 크로마토그래피를 이용한 55Fe와 59/63Ni의 화학분리 중 목적원소 및 방해원소 거동 특성 연구
- 진단참고 준위를 적용한 선량 변화에 따른 영상 품질의 변화 평가
- 호주 방사선 의료 전문가 면허제도 및 교육과정 고찰: 진단방사선사를 중심으로
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!
