본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

치밀형 유방에서 유방특이감마영상검사의 유용성 평가

이용수 0

영문명
A Study on Comparative Analysis of Mammography and Tc-99m MIBI Scintimammography for Dense Breast
발행기관
대한핵의학기술학회
저자명
정은미(Eun Mi Jeong) 김호성(Ho Seong Kim)
간행물 정보
『핵의학기술』Vol.16 No.1, 76~79쪽, 전체 4쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2012.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: This study was to evaluate usefulness of ⁹⁹ᵐTc-MIBI scintimammography for dense breast by comparing concordance in test results between Tc-⁹⁹ᵐ MIBI scintimammography and mammography whose effect was proved the most as an imaging tool depending on breast density and at the same time by examining limitation on evaluation depending on density of breast tissue. [Materials and Methods] In the period from December 2010 to July 2011, this study targeted 150 patients who took both of ⁹⁹ᵐTc-MIBI scintimammography and mammography conducted by using breast gamma camera in this hospital. Breast density was classified to the four levels of pattern 1 ~4 based on the results of mammography. ⁹⁹ᵐTc-MIBI scintimammography was conducted with the LCC, the RCC, the LMLO, and the RML one minute after intravenous injection of ⁹⁹ᵐTc-MIBI 7400 MBq (20 mCi) while analysis was made for concordance in test results of ⁹⁹ᵐTc-MIBI scintimammography and mammography. [Results] Among the 150 patients, pattern 1 was found in 3 patients, pattern 2 in 44 patients, pattern 3 in 61 patients, and pattern 4 in 37 patients. There were 5 patients who showed the case where it was impossible to determine density of breast tissue due to foreign body inserted to breast. The concordance ratio of the results between ⁹⁹ᵐTc-MIBI scintimammography and mammography was 95.5% for pattern 2, 95.1% for pattern 3 and 94.6% for pattern 4. This demonstrated that the concordance rate decreased according to the increase in breast density. [Conclusion] When there was limitation on evaluation of breast specific gamma imaging test results due to increased intake in breast tissue or surgical site, the concordance rate was 6.8% for pattern 2, 16.3% for pattern 3 and 18.9% for pattern 4. This demonstrated that the degree of limitation on evaluation of breast specific gamma imaging test results increased according to the increase in breast density.

목차

서론
대상 및 방법
결과
고찰 및 결론
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

정은미(Eun Mi Jeong),김호성(Ho Seong Kim). (2012).치밀형 유방에서 유방특이감마영상검사의 유용성 평가. 핵의학기술, 16 (1), 76-79

MLA

정은미(Eun Mi Jeong),김호성(Ho Seong Kim). "치밀형 유방에서 유방특이감마영상검사의 유용성 평가." 핵의학기술, 16.1(2012): 76-79

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제