Myocardial SPECT시 COR에서 위치변화에 따른 Image Uniformity 비교

이용수 0

영문명
Comparison of Image Uniformity Due to Position Shifting in COR on Myocardial SPECT
발행기관
대한핵의학기술학회
저자명
임현진(Hyun Jin Lim) 김중현(Joong Hyun Kim) 김재일(Jae Il Kim) 임정진(Jung Jin Lim) 김진의(Jin Eui Kim) 김현주(Hyun Joo Kim) 이재성(Jae Sung Lee) 이동수(Dong Soo Lee)
간행물 정보
『핵의학기술』Vol.16 No.1, 70~75쪽, 전체 6쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2012.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: It is important to acquire accurate data because the SPECT scan affected by various physical factors. The aim of this study was to compare the uniformity when both centers were matched or mismatched differed from position of heart in COR. Materials and methods: The images were acquired with cylindrical uniform phantom (6.7 cm diameter, 9 cm length) and heart insert phantom using Cardio MD SPECT system (Philips, USA). The phantoms were positioned on COR as well as four different points which were 10 cm above, below, left and right side from the COR. The counts from the both edge of cylindrical uniform phantom and those from the both wall of heart insert phantom were compared by using vertical and horizontal line profile. In addition, the qualitative evaluation was performed with heart insert phantom images and volunteer test. Results: In heart insert phantom study, the differences of counts between COR and 10 cm above, below, left and right point of COR were 1.1, 4.1, 4.9, 2.2 and 0.9% using T-A curve for horizontal view. In case of vertical view of COR 3.9, 21.9, 3.5, 23.9, 14.0% were shown. In cylindrical phantom study, the differences of counts between COR and 10 cm above, below, left and right point of COR were 4.3, 0.3, 3.3, 2.6 and 0.7% using T-A curve for horizontal view. In case of vertical view of COR 2.7, 3.0, 1.0, 0.3, 3.4% were shown. For qualitative evaluation, the images at COR were the most uniform for both of heart insert phantom and volunteer test, whereas other four positions showed somewhat distorted images. Conclusion: It showed the most uniform images when COR is matched with the heart. Therefore, we can expect that distortion which increased or decreased of myocardial perfusion will be prevented by matching the heart and COR when positioning. Furthermore, the accuracy of diagnosis will be improved as well.

목차

서론
실험재료 및 방법
결과
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

임현진(Hyun Jin Lim),김중현(Joong Hyun Kim),김재일(Jae Il Kim),임정진(Jung Jin Lim),김진의(Jin Eui Kim),김현주(Hyun Joo Kim),이재성(Jae Sung Lee),이동수(Dong Soo Lee). (2012).Myocardial SPECT시 COR에서 위치변화에 따른 Image Uniformity 비교. 핵의학기술, 16 (1), 70-75

MLA

임현진(Hyun Jin Lim),김중현(Joong Hyun Kim),김재일(Jae Il Kim),임정진(Jung Jin Lim),김진의(Jin Eui Kim),김현주(Hyun Joo Kim),이재성(Jae Sung Lee),이동수(Dong Soo Lee). "Myocardial SPECT시 COR에서 위치변화에 따른 Image Uniformity 비교." 핵의학기술, 16.1(2012): 70-75

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제