방사성의약품 투여 시 피폭선량 저감에 대한 연구

이용수 0

영문명
The Study of Radiation Reducing Method during Injection Radiopharmaceuticals
발행기관
대한핵의학기술학회
저자명
조석원(Seok Won Cho) 정석(Seok Jung) 박준영(June Young Park) 오신현(Shin Hyun Oh) 남궁혁(Hyuk Namkoong) 오기백(Ki Beak Oh) 김재삼(Jae Sam Kim) 이창호(Chang Ho Lee)
간행물 정보
『핵의학기술』Vol.16 No.1, 80~85쪽, 전체 6쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2012.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: The whole body bone scan is an examination that visualizing physiological change of bones and using bone-congenial radiopharmaceutical. The patients are intravenous injected radiopharmaceutical which labeled with radioactive isotope (⁹⁹ᵐTc) emitting 140 keV gammarays and scanned after injection. The 3 principles of radiation protection from external exposureare time, distance and shielding. On the 3 principles of radiation protection basis, radiopharmaceutical might just as well be injected rapidly for reducing radiation because it might be the unopened radiation source. However the radiopharmaceuticals are injected into patient directly and there is a limitation of distance control. This study confirmed the change of radiation exposure as change of distance from radiopharmaceutical and observed the change of radiation exposure afte rsetting a shelter for help to control radio-technician’s exposure. Materials & methods: For calculate the average of injection time, the trained injector measured the injection time for 50 times and calculated the average (2 minutes). We made a source as filled the ⁹⁹ᵐTc-HDP 925 MBq 0.2 mL in a 1 mL syringe and measured the radiation exposure from 50 cm,100 cm,150 cm and 200 cm by using Geiger-Mueller counter (FH-40, Thermo Scientific, USA). Then we settled a lead shielding (lead equivalent 6 mm) from the source 25 cm distance and measured the radiation exposure from 50 cm distance. For verify the reproducibility, the measurement was done among 20 times. The correlation between before and after shielding was verified by using SPSS (ver. 18) as paired t-test. Results: The radiation doses according to distance during 2 minutes from the source without shielding were 1.986±0.052 μ Sv in 50 cm, 0.515±0.022 μSv in 100 cm, 0.251±0.012 μSv in 150 cm, 0.148±0.006 μSv in 200 cm. After setting the shielding, the radiation dose was 0.035±0.003 μSv. Therefore, there was a statistical significant difference between the radiation doses with shielding and without shielding (p<0.001). Conclusion: Because the great importance of whole body bone scan in the nuclear medicine, we should make an effort to reduce radiation exposure during radiopharmaceutical injections by referring the principles of radiation protection from external exposure. However there is a limitation of distance for direct injection and time for patients having attenuated tubules. We confirmed the reduction of radiation exposure by increasing distance. In case of setting shield from source 25 cm away, we confirmed reducing of radiation exposure. Therefore it would be better for reducing of radiation exposure to using shield during radiopharmaceutical injection.

목차

서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

조석원(Seok Won Cho),정석(Seok Jung),박준영(June Young Park),오신현(Shin Hyun Oh),남궁혁(Hyuk Namkoong),오기백(Ki Beak Oh),김재삼(Jae Sam Kim),이창호(Chang Ho Lee). (2012).방사성의약품 투여 시 피폭선량 저감에 대한 연구. 핵의학기술, 16 (1), 80-85

MLA

조석원(Seok Won Cho),정석(Seok Jung),박준영(June Young Park),오신현(Shin Hyun Oh),남궁혁(Hyuk Namkoong),오기백(Ki Beak Oh),김재삼(Jae Sam Kim),이창호(Chang Ho Lee). "방사성의약품 투여 시 피폭선량 저감에 대한 연구." 핵의학기술, 16.1(2012): 80-85

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제