방사성의약품 투여 시 피폭선량 저감에 대한 연구
이용수 0
- 영문명
- The Study of Radiation Reducing Method during Injection Radiopharmaceuticals
- 발행기관
- 대한핵의학기술학회
- 저자명
- 조석원(Seok Won Cho) 정석(Seok Jung) 박준영(June Young Park) 오신현(Shin Hyun Oh) 남궁혁(Hyuk Namkoong) 오기백(Ki Beak Oh) 김재삼(Jae Sam Kim) 이창호(Chang Ho Lee)
- 간행물 정보
- 『핵의학기술』Vol.16 No.1, 80~85쪽, 전체 6쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2012.04.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose: The whole body bone scan is an examination that visualizing physiological change of bones and using bone-congenial radiopharmaceutical. The patients are intravenous injected radiopharmaceutical which labeled with radioactive isotope (⁹⁹ᵐTc) emitting 140 keV gammarays and scanned after injection. The 3 principles of radiation protection from external exposureare time, distance and shielding. On the 3 principles of radiation protection basis, radiopharmaceutical might just as well be injected rapidly for reducing radiation because it might be the unopened radiation source. However the radiopharmaceuticals are injected into patient directly and there is a limitation of distance control. This study confirmed the change of radiation exposure as change of distance from radiopharmaceutical and observed the change of radiation exposure afte rsetting a shelter for help to control radio-technician’s exposure. Materials & methods: For calculate the average of injection time, the trained injector measured the injection time for 50 times and calculated the average (2 minutes). We made a source as filled the ⁹⁹ᵐTc-HDP 925 MBq 0.2 mL in a 1 mL syringe and measured the radiation exposure from 50 cm,100 cm,150 cm and 200 cm by using Geiger-Mueller counter (FH-40, Thermo Scientific, USA). Then we settled a lead shielding (lead equivalent 6 mm) from the source 25 cm distance and measured the radiation exposure from 50 cm distance. For verify the reproducibility, the measurement was done among 20 times. The correlation between before and after shielding was verified by using SPSS (ver. 18) as paired t-test. Results: The radiation doses according to distance during 2 minutes from the source without shielding were 1.986±0.052 μ Sv in 50 cm, 0.515±0.022 μSv in 100 cm, 0.251±0.012 μSv in 150 cm, 0.148±0.006 μSv in 200 cm. After setting the shielding, the radiation dose was 0.035±0.003 μSv. Therefore, there was a statistical significant difference between the radiation doses with shielding and without shielding (p<0.001). Conclusion: Because the great importance of whole body bone scan in the nuclear medicine, we should make an effort to reduce radiation exposure during radiopharmaceutical injections by referring the principles of radiation protection from external exposure. However there is a limitation of distance for direct injection and time for patients having attenuated tubules. We confirmed the reduction of radiation exposure by increasing distance. In case of setting shield from source 25 cm away, we confirmed reducing of radiation exposure. Therefore it would be better for reducing of radiation exposure to using shield during radiopharmaceutical injection.
목차
서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES
해당간행물 수록 논문
- 수신증을 진단 받은 소아 환자의 DMSA 신장 검사에서 정확한 관심영역 설정에 대한 고찰
- 단 반감기 핵종을 이용한 PET 검사 시 영상 획득 시간에 따른 정량성 평가
- 핵의학 검체검사 정도관리의 개선을 위한 Westgard Multi-Rules의 적용
- Tl-201을 이용한 심근관류 SPECT에서 Body contour와 Circular mode의 영상 획득 차이에 따른 영상의 질 비교
- 자동합성장치에 따른 ¹⁸F-FDG의 방사선분해 평가
- ⁹⁹ᵐTc-HMPAO 뇌혈류 SPECT 검사 시 환자에 따른 뇌조직 추출률에 대한 고찰
- 핵의학과 전용화장실에서 측정된 표면오염도 및 공간선량율에 대한 연구
- 전신 PET/CT 검사에서 환자의 팔 위치에 따른 CT 유효선량의 비교 연구
- 치밀형 유방에서 유방특이감마영상검사의 유용성 평가
- List Mode에서 PET/CT Scanner의 직선성 평가
- 방사성의약품 투여 시 피폭선량 저감에 대한 연구
- Myocardial SPECT시 COR에서 위치변화에 따른 Image Uniformity 비교
- 게이트심장혈액풀 스캔에서 환자의 자세 변화에 따른 심박출계수의 변화 연구
- 게이트 심장 혈액풀 스캔에서 좌전사위상 각도의 변화에 따른 정량적 지표 비교
- PET/CT 검사에서 SharpIR 재구성 방법의 평가
- Article TOF 기법을 이용한 PET/CT 검사에서 적정 스캔 시간에 대한 정량적 평가
- 핵의학과 환경미화원의 일시 출입자 분류에 대한 고찰
- ⁹⁹ᵐTc 표지화합물을 사용한 심근 관류 SPECT 검사에서 심장과 타 장기와의 중첩 방지를 위한 자세 변화의 유용성
- 동적 신장 신티그래피 검사 시 사용되는 Gates 법과 Modified Gates 법의 사구체 여과율 비교에 관한 고찰
- BIO-RAD 정도관리 물질을 이용한 방사면역측정법의 Acceptable Range 설정에 대한 제언
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- CT contrast 검사 시 중심 정맥관을 이용한 조영제 사용에 대한 연구
- CT조영제 부작용 고위험군에 대한 전처치의 유용성
의약학 > 방사선과학분야 NEW
- 초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구
- 방사선에 대한 지식 및 인식도 연구
- 입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!