본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

전신 PET/CT 검사에서 환자의 팔 위치에 따른 CT 유효선량의 비교 연구

이용수 0

영문명
A Comparative Study on the CT Effective Dose by the Position of Patient’s Arm
발행기관
대한핵의학기술학회
저자명
성지혜(Ji Hye Seong) 박순기(Soon Ki Park) 김정선(Jung Sun Kim) 박승용(Seung Yong Park) 정우영(Woo Young Jung)
간행물 정보
『핵의학기술』Vol.16 No.1, 44~49쪽, 전체 6쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2012.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: In the whole body PET/CT scan, it is natural to lift the patient’s arm for its quality improvement. However, when the lesion is located in head and neck, the arms should be located lower. This study was designed to compare the CT effective dose for each arm position applying Automatic Exposure Control (AEC). Materials and Methods: 45 patients who had ¹⁸F-FDG whole body PET/CT scan were studied with Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY), Discovery STe 8 (GE healthcare, USA). The CT effective dose of 15 patients for each equipment was measured and comparatively analyzed in both arm-lifted position and lower-arm position. ImPACT v1.0 program was used as the method of measurement for CT effective dose. For the statistics analysis, Paired t-test which paired with SPSS 18.0 statistic program was applied. Results: In the case of arm-lifted, it was measured as 6.33±0.93 mSv for Biograph Sensation 16, 8.01±1.34 mSv for Biograph Truepoint 40, and 9.69±2.32 mSv for Discovery STe 8. When arms are located lower position, it was measure as 6.97±0.76 mSv, 8.95±1.85 mSv, 13.07±2.87 mSv for each. CT effective dose according to the arm position was 9.2% for Biograph Truepoint 40, 10.5% for Biograph Sensation 16, and 25.9% for Discovery Ste 8. The statistics analysis showed the meaningful difference (p<0.05). Conclusion: For the whole body PET/CT case, CT effective dose applying AEC was decreased the radiation exposure of the patients when the arm was lifted for 15.2% of average value. The patient who has no lesion in head and neck would decrease the artifact occurrence in objective part and lower the CT effective dose. Also, for the patient who had lesion in head and neck, the artifact in objective part can be lower by putting the arms down, the fact that CT effective dose increases should be concerned in its whole body PET/CT scan.

목차

INTRODUCTION
MATERIALS AND METHOD
RESULTS
DISCUSSION
CONCLUSION
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

성지혜(Ji Hye Seong),박순기(Soon Ki Park),김정선(Jung Sun Kim),박승용(Seung Yong Park),정우영(Woo Young Jung). (2012).전신 PET/CT 검사에서 환자의 팔 위치에 따른 CT 유효선량의 비교 연구. 핵의학기술, 16 (1), 44-49

MLA

성지혜(Ji Hye Seong),박순기(Soon Ki Park),김정선(Jung Sun Kim),박승용(Seung Yong Park),정우영(Woo Young Jung). "전신 PET/CT 검사에서 환자의 팔 위치에 따른 CT 유효선량의 비교 연구." 핵의학기술, 16.1(2012): 44-49

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제