본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

산화물을 첨가한 HgI2 엑스선 검출기의 특성 평가

이용수 10

영문명
A Performance Analysis of HgI2 X-ray Detector Mixed Oxidation Materials
발행기관
한국방사선학회
저자명
신정욱(Jungwook Shin) 김진선(Jinseon Kim) 조규석(Gyuseok Jo) 오경민(Kyungmin Oh) 김교태(Kyotae kim) 강상식(Sangsik Kang) 남상희(Sanghee Nam)
간행물 정보
『한국방사선학회 학술대회 논문집』한국방사선학회 2014년 춘계종합학술대회논문집, 137~149쪽, 전체 13쪽
주제분류
공학 > 기타공학
파일형태
PDF
발행일자
2014.05.31
3,240

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

To improve the performance of HgI2 composite x-ray detector, we studied its structure that reduced charge trap and estimated electrical properties as incident x-ray energy. The composite detector exhibits lower performance in x-ray sensitivity, dark current, and reproducibility than single-crystal detector or poly-crystal detector, because dielectric constant of polymeric glue and grain size of semiconductor particles affected charge transport properties. Therefore, in order to improve the charge transport properties, metal oxide such as SiO2 or TiO2 were added to HgI2 composite x-ray detector and its characteristics were investigated. The effect of metal oxide in HgI2 composite was analysed by comparing the properties of metal oxide mixed HgI2 composite x-ray detector with those of simple HgI2 composite x-ray detector. The samples were divided into three kinds of films, HgI2/TiO2 composite x-ray detector, HgI2/SiO2 composite x-ray detector, and simple HgI2 composite x-ray detector. All samples were fabricated by sedimentation method, one kind of particle-in-binder (PIB) methods. And the each thickness of them was around 200um. To investigate electrical properties of the samples, dark current of samples was measured as a function of applied bias. As a result, when 1 V/um of the electric field was applied, 4.78 nA/cm2, 16.58 nA/cm2, and 7.10 nA/cm2 were measured for HgI2/SiO2 composite x-ray detector, HgI2/TiO2 composite x-ray detector, and simple HgI2 composite x-ray detector. And then x-ray sensitivity of samples was measured in RQA-5 condition (70kVp, 100mA, 0.03s, 21mmAl phantom). The result respectively showed 23.15 nC/mR/cm2, 19.25 nC/mR/cm2, and 24.25 nC/mR/cm2 of x-ray sensitivity for the each samples. Furthermore, reproducibility, aging effect, and signal lag of samples were measured. Consequentially, the all measured results like dark current, x-ray sensitivity, reproducibility, and signal lag showed the best properties in HgI2/SiO2 composite x-ray detector among three kinds of samples

목차

I. Introduction
II. Experimental Setup
III. Results and discussion
IV. Conclusion

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

신정욱(Jungwook Shin),김진선(Jinseon Kim),조규석(Gyuseok Jo),오경민(Kyungmin Oh),김교태(Kyotae kim),강상식(Sangsik Kang),남상희(Sanghee Nam). (2014).산화물을 첨가한 HgI2 엑스선 검출기의 특성 평가. 한국방사선학회 학술대회 논문집, 2014 (5), 137-149

MLA

신정욱(Jungwook Shin),김진선(Jinseon Kim),조규석(Gyuseok Jo),오경민(Kyungmin Oh),김교태(Kyotae kim),강상식(Sangsik Kang),남상희(Sanghee Nam). "산화물을 첨가한 HgI2 엑스선 검출기의 특성 평가." 한국방사선학회 학술대회 논문집, 2014.5(2014): 137-149

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제