본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

소아의 실용적인 뇌압측정 방법

이용수 20

영문명
A practical mehod of estimating CSF pressure in children
발행기관
대한소아신경학회
저자명
정상덕(Sang Deug Chung) 이건수(Keon Su Rhee)
간행물 정보
『Annals of Child Neurology(구 대한소아신경학회지)』대한소아신경학회지 제1권 제2호, 26~32쪽, 전체 7쪽
주제분류
의약학 > 의학일반
파일형태
PDF
발행일자
1993.12.20
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Lumbar puncture has been to obtain CSF fluid for analysis and to measure CSF pressure, But, it is often difficult to measure CSF pressure in children. The flow of CSF through a spinal needle is described by equation: Flow = pressure/(needle constant X relative vescosity). Thus, the CSF flow rate(drops.30 sec) during lumbar puncture can be used to estimate CSF pressure. The CSF viscosity was approximately the same as the viscosity of 0.9% NaCI(relative viscosity = 1.02 at between 20℃ and 37℃). Based on this characterstics, normal saline was used to model CSF flow in vitro. The counting drops of CSF and 26℃ 0.9%NaCI for 30 sec through three spinal needle(22G, 21G, 20G, 3.5 inches) was measured at a given pressure (CmH2O). From January 1993 to jun 1993, the authers measured CSF pressure in a series of 80 children with CNS disease, leukemia, and other malignancy who admitted at dept. of pediatrics, college of medicine, Chungnam national university hospital, The summary of results were as follows: 1. The needles constants(mean + SD) for the 22-gauge 3.5 inch, 21- gauge 3.5 inch, and 20-gauge 3.5 inch spinal needles were 1.534 ± 0.066, 0.905 ± 0.038. 0.476 ± 0.013 CmH2O/Drop/30 sec, respectively. Above results were simply descrbed by the equation; P ≒ 1.5 X D, P ≒ 0.9 X D, P ≒ 0.5 X D(P = pressure CmH20, D = drops/ 30sec, G = gauge). 2. Dripping rate was related linearly to pressure for each size needle. 3. Bacause viscosity is temperature-dependent, flow rate through a spinal needle was increased at a high thmperature. Because the drops can bo counted while fluid is being collected, this method is more convenient tham manometric pressure measurement. Eliminating the use of manometer also simplifies the proceduer, reduces supply cost and time, and may avoid the problem of manometric pressure measurement such as pain or air bubbles.

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

정상덕(Sang Deug Chung),이건수(Keon Su Rhee). (1993).소아의 실용적인 뇌압측정 방법. Annals of Child Neurology(구 대한소아신경학회지), 1 (2), 26-32

MLA

정상덕(Sang Deug Chung),이건수(Keon Su Rhee). "소아의 실용적인 뇌압측정 방법." Annals of Child Neurology(구 대한소아신경학회지), 1.2(1993): 26-32

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제