본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

PET/CT 검사에서 비스무스(bismuth) 차폐체의 적용에 따른 유용성 평가

이용수 0

영문명
The Usability Evaluation According to the Application of Bismuth Shields in PET/CT Examination
발행기관
대한핵의학기술학회
저자명
남궁식(Sik Nam-Kung) 김지현(Ji Hyeon Kim) 이주영(Ju young Lee) 박훈희(Hoon Hee Park)
간행물 정보
『핵의학기술』Vol.17 No.1, 36~42쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2013.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: Recently with CT developed, various studies for reduction of exposure dose is underway. Study of bismuth shields in these studies is actively underway, and has already been applied in the clinical. However, the application of the PET/CT examination was not activated. Therefore, through this study, depending on the application of bismuth shields in the PET/CT examination, we want to identify the quality of the image and the impact on the SUV. Materials and Methods: In this study, to apply to the shielding of the breast, by using the bismuth shields that contains 0.06 mmPb ingredients, was applied to the PET/CT GEMINI TF 64 (Philips Healthcare, Cleveland, USA). Phantom experiments using the NEMA IEC Body Phantom, images were acquired according to the presence or absence of bismuth shields apply. Also, When applying, images were obtained by varying the spacing 0, 1, 2 cm each image set to the interest range in the depth of the phantom by using EBW-NM ver.1.0. Results: When image of the PET Emission acquires, the SUV was in increased depending on the use of bismuth shields, difference in the depth to the surface from deep in the phantom increasingly SUV increased (P<0.005). Also, when using shields, as the more gab decreased, SUV is more increased (P<0.005). Conclusion: Through this study, PET/CT examination by using of bismuth shields which is used as purpose of reduction dose be considered. When using shields, the difference of SUV resulting from the application of bismuth shields exist and that difference is more decreased as gab of shields and surface is wider. Therefore, setting spacing of shield should be considered, if considering the reduction of the variation of SUV and image quality, disease of deep or other organs should be a priority rather than superficial disease. Through this study, when applying identified to clinical examination, the reduction of unnecessary exposure is considered.

목차

서론
대상 및 방법
결과
고찰
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

남궁식(Sik Nam-Kung),김지현(Ji Hyeon Kim),이주영(Ju young Lee),박훈희(Hoon Hee Park). (2013).PET/CT 검사에서 비스무스(bismuth) 차폐체의 적용에 따른 유용성 평가. 핵의학기술, 17 (1), 36-42

MLA

남궁식(Sik Nam-Kung),김지현(Ji Hyeon Kim),이주영(Ju young Lee),박훈희(Hoon Hee Park). "PET/CT 검사에서 비스무스(bismuth) 차폐체의 적용에 따른 유용성 평가." 핵의학기술, 17.1(2013): 36-42

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제