본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

18F-FDG Brain PET/CT 검사를 위한 데이터 비교 방법의 평가

이용수 0

영문명
Evaluation of Database Comparison Methods for 18F-FDG Brain PET/CT
발행기관
대한핵의학기술학회
저자명
도용호(Yong Ho Do) 이홍재(Hong Jae Lee) 김진의(Jin Eui Kim)
간행물 정보
『핵의학기술』Vol.19 No.1, 62~66쪽, 전체 5쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2015.05.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose Various database comparison methods(DCM) are used for analyzing functional neuro-imaging. It is possible to statistically evaluate decreased or increased metabolism of abnormal patient's brain by comparing with asymptomatic controls in DCM. And results of DCM are additionally used for easily explaining defect region. The aim of this study was to evaluate usefulness of statistical parametric mapping(SPM) and scenium. Materials and Methods Data of 15 patients(62.02±15.03 year) underwent ¹⁸F-FDG brain PET/CT were collected and analyzed. Biograph TruePoint 40 with TrueV, (Siemens) was used as a PET/CT scanner. Scenium(version 4.0) in Syngo.via(version VA30A) and SPM99 were applied for statistical evaluation. Consistency between PET reading and result of DCM were evaluated by 5 nuclear medicine physicians through a questionnaire survey. SUV and SD changes were evaluated by changing iteration, gaussian filter and matrix size in scenium. And average required time for generating result of SPM99 and scenium was compared by 3 medical technologists. Results Consistency from the result of SPM99 and scenium showed 84% and 92.4% compare to PET reading. When iteration 4, FWHM 8 and matrix size 168, SUV and SD were decreased by 0.59%, 8.73%, 4.69%, 20.38% and 0.88%, 8.25% respectively compare to routine parameter(iteration 8, FWHM 2 and matrix size 336) of scenium. Average required time of SPM99 and Scenium took 282 seconds and 116 seconds to generate result. Conclusion Results of SPM99 and Scenium showed high consistency compare to PET reading. Various parameters can be controled by user when using SPM. However, normal database needs to be acquired. And it takes significant amount of time and effort for the first set up. On the other hand, Scenium provides normal database even though modifiable parameters are limited. Therefore, more informations could be provided for brain PET/CT if properly understanding and selecting each DCM.

목차

서론
실험재료 및 방법
결과
결론
요약
Reference

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

도용호(Yong Ho Do),이홍재(Hong Jae Lee),김진의(Jin Eui Kim). (2015).18F-FDG Brain PET/CT 검사를 위한 데이터 비교 방법의 평가. 핵의학기술, 19 (1), 62-66

MLA

도용호(Yong Ho Do),이홍재(Hong Jae Lee),김진의(Jin Eui Kim). "18F-FDG Brain PET/CT 검사를 위한 데이터 비교 방법의 평가." 핵의학기술, 19.1(2015): 62-66

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제